FAQ - Frequently Asked Questions
- Products Search > Materials Testing & Inspection
Keyword Search
Materials Testing & Inspection
Frequently Referenced FAQ
FAQ within [ Materials Testing & Inspection ]
-
(HMV) The ready lamp and the running lamp blink
Replace the battery on the CPU board. Contact a Shimadzu sales or service representative. Show Detail
- No:7506
- Date of Issue:2021/12/06 10:05
- Category: Micro Hardness Tester(HMV)
-
(DUH) Illumination Lamp Replacement
Part Number:347-24149-01 Illumination Lamp 1. Remove upper cover. 2.Remove lamp ASSY and install new lamp ASSY. 3.Close the top cover, an... Show Detail
- No:7514
- Date of Issue:2021/12/06 10:05
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
-
When the tip of the indenter breaks or you wish to replace the indenter with a different type, perform the following procedure. Part Number:340-47013 Triang... Show Detail
- No:7515
- Date of Issue:2021/12/06 10:05
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
-
(DUH) Centering an Indentation
If the indenter lowering position is deviated from the center of the visual field, perform the following procedure: 1. Remove the front cover. 1) R... Show Detail
- No:7516
- Date of Issue:2021/12/06 10:05
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
-
(DUH) Indenter Height Adjustment
When the microscope focal point is adjusted and the stage is moved to under the indenter before a test is started, if the indenter touches the sample or the ... Show Detail
- No:7518
- Date of Issue:2021/12/06 10:05
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
-
(DUH) Objective Lens Replacement
Replacing the x50 objective lens: Part Number:344-89964-40 Objective lensx50 If the objective lens is damaged or the lens visibility is deteriorated ... Show Detail
- No:7520
- Date of Issue:2021/12/06 10:05
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
-
(DUH) Identical Focal Point Adjustment
1. While observing a sample through the x50 objective lens, move the stage up/down by using the elevating handle to perform focal point adjustment. 2. Switc... Show Detail
- No:7521
- Date of Issue:2021/12/06 10:05
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
-
(HMV) Replacing and Adjusting the Objective Lens
Adjust the magnification as indicated below if the optical head has been removed, if theobjective lens has been replaced, or if the magnification is unsuitab... Show Detail
- No:7478
- Date of Issue:2021/12/06 11:21
- Category: Micro Hardness Tester(HMV)
- Brached FAQ
-
(DUH) Magnification Adjustment
1. Make sure that the cables are properly connected. Turn ON the power supply. And please let me turn on a lamp. When you do not switch on the light, please ... Show Detail
- No:7522
- Date of Issue:2021/12/06 11:21
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
- Brached FAQ
-
(HMV) Camera Attachment Position and Focusing Adjustments
Before performing magnification and image center adjustments, adjust the camera's attachment position until the image observed through the tester's eyepiece ... Show Detail
- No:7481
- Date of Issue:2021/12/06 11:48
- Category: Micro Hardness Tester(HMV)
81-90 of Total 211