FAQ - Frequently Asked Questions
- Products Search > Materials Testing & Inspection
Keyword Search
Materials Testing & Inspection
Frequently Referenced FAQ
FAQ within [ Materials Testing & Inspection ]
-
(EZ-Test) Calibrating Test Force (E-CAL)
Electronically calibrates (E-CAL) the test force. Calibrating the test force with E-CAL usesprecision resistors built into the calibration cable to apply a s... Show Detail
- No:7668
- Date of Issue:2022/01/19 13:10
- Last Updated:2022/01/19 13:41
- Category: EZ-Test Series
-
(EZ-Test) In an Emergency / During a Power Outage
If a malfunction occurs, such as the crosshead not stopping, a burning odor being emitted, ora power failure, take the following actions. Then inspect the s... Show Detail
- No:7665
- Date of Issue:2022/01/19 11:36
- Last Updated:2022/01/21 10:40
- Category: EZ-Test Series
-
(DUH) Balance Adjustment/Depth Detector Adjustment
If the DUH series hardness tester normally operates, the test status displayed in the test window is changed to “Indenter down” and the displayed test force ... Show Detail
- No:7517
- Date of Issue:2021/12/16 14:45
- Category: Dynamic Ultra-micro Hardness Tester(DUH)
- Brached FAQ
-
1.With the Hydraulic Power Supply stopped, screw the "Screw Rod" into the center of the actuator piston tip. 2.After inserting "Ring Wedge" into "Screw Rod"... Show Detail
- No:7600
- Date of Issue:2021/12/08 15:45
- Category: EHF Series
- Brached FAQ
-
1.After starting the Hydraulic Power Supply, press the LOAD key on the front of the control unit. 2.A confirmation screen is displayed on the LCD panel. Pre... Show Detail
- No:7598
- Date of Issue:2021/12/08 09:27
- Category: EHF Series
- Brached FAQ
-
To ensure proper operation of the equipment, check the following before using it. 1.Check that the power cables of the control unit, Hydraulic Power Supply,... Show Detail
- No:7597
- Date of Issue:2021/12/08 09:27
- Category: EHF Series
- Brached FAQ
-
(EHF) The set displacement amplitude does not appear
Automatic control during testing with Type 1 calculates with the supply pressure set in the detailed supply pressure. If the supply pressure of the hydraulic... Show Detail
- No:7644
- Date of Issue:2021/12/07 10:15
- Category: Windows Software for 4830
-
(EHF) The set maximum test force cannot be loaded / The s...
The maximum testable condition is a reference value. We do not guarantee the actual test. Depending on the state of the device, the value may not be. If the ... Show Detail
- No:7643
- Date of Issue:2021/12/07 10:15
- Category: Windows Software for 4830
-
(EHF) The display does not change when the Phase unit set...
Changing the 'Phase unit' setting is only effective for an optionaltest. Show Detail
- No:7642
- Date of Issue:2021/12/07 10:15
- Category: Windows Software for 4830
-
(EHF) The display does not change when the language setti...
The software must be restarted after the language setting ischanged. The change will take effect after the software isrestarted. Show Detail
- No:7641
- Date of Issue:2021/12/07 10:15
- Category: Windows Software for 4830
51-60 of Total 211