Frequently Referenced FAQ
FAQ within [ HPLC ]
-
«Main Cause» The illumination circuit is not functioning properly. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service ... Show Detail
- No:4124
- Date of Issue:2020/12/02 16:46
- Category: Detector
-
«Main Cause» Detector initialization failed. «Countermeasure» Implement corrective measures in the following sequence. (1) Reconfirm that the flow cell is i... Show Detail
- No:4125
- Date of Issue:2020/12/02 16:46
- Category: Detector
-
«Main Cause» The illumination circuit is not functioning properly. «Countermeasure» Replace the D2 lamp. Click here for Replacement method of... Show Detail
- No:4126
- Date of Issue:2020/12/02 16:46
- Last Updated:2020/12/07 11:05
- Category: Detector
-
«Main Cause» The illumination circuit is not functioning properly. «Countermeasure» Replace the D2 lamp. Click here for Replacement method of... Show Detail
- No:4127
- Date of Issue:2020/12/02 16:46
- Last Updated:2020/12/07 11:06
- Category: Detector
-
«Main Cause» The illumination circuit is not functioning properly. «Countermeasure» Replace the D2 lamp. Click here for Replacement method of... Show Detail
- No:4128
- Date of Issue:2020/12/02 16:46
- Last Updated:2020/12/07 11:06
- Category: Detector
-
«Main Cause» A rotation problem was detected for the internal fan. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service ... Show Detail
- No:4129
- Date of Issue:2020/12/02 16:46
- Category: Detector
-
«Main Cause» The monochromator became hot. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:4130
- Date of Issue:2020/12/02 16:46
- Category: Detector
-
«Main Cause» A broken circuit may have occurred in the monochromator temperature sensor. «Countermeasure» Switch the instrument power OFF and contact a Shim... Show Detail
- No:4131
- Date of Issue:2020/12/02 16:46
- Category: Detector
-
«Main Cause» PDA detector initialization failed. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:4132
- Date of Issue:2020/12/02 16:46
- Category: Detector
-
«Main Cause» Detector data processing did not function properly. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service re... Show Detail
- No:4133
- Date of Issue:2020/12/02 16:46
- Category: Detector
771-780 of Total 941