• Font Size
  • S
  • M
  • L

Frequently Referenced FAQ

FAQ within [ Common ]

1-10 of Total 34

1 / 4page
  • Nexera 40 Series Operation mode

    If you are using a new instrument and the software does not support it, you cancontrol it by setting the following operation modes. Please refer the manual ... Show Detail

    • No:9171
    • Date of Issue:2023/06/09 15:04
  • (LC) Settings for Fast Analysis (UHPLC)

    1. Setting the Fast LC Mode Fast LC (Mode): Select this for fast gradient analysis, such as when the mobile phase ratio is changed within 3 minutes. This m... Show Detail

    • No:6930
    • Date of Issue:2021/09/10 13:25
  • (LC) Consumable (Connector)

    Show Detail

    • No:6916
    • Date of Issue:2021/09/06 16:07
    • Brached FAQ
  • Maintenance for Nexera (LC-40) series (Video)

    Maintenance for Nexera (LC-40) series (Video) Please select a model. •Clich here for Maintenance for LC-40 (Pump) series (Video) - Replacing the... Show Detail

    • No:6633
    • Date of Issue:2021/07/26 13:23
  • (HPLC) Check the Condition of Consumables (System Check)

    By executing the system check, you can check the usage of consumables for the entire system. • LCsolution, LabSolutions To open the [System Check] sub-wi... Show Detail

    • No:4965
    • Date of Issue:2021/02/05 10:54
    • Last Updated:2026/02/19 16:03
  • (HPLC) Non-injection method (Without sample)

    LCsolution, LabSolutions, how to do non-injection when the system includes an autosampler. Vial#:Sets the vial No. of the autosampler to be used for dat... Show Detail

    • No:4925
    • Date of Issue:2021/02/05 10:54
    • Last Updated:2021/02/09 08:52
  • HPLC: What solvent cannot be used?

    • It is basically used within the pH described in the specifications of the instruction manual of each instruments. • Not covered by warranty if used ... Show Detail

    • No:4633
    • Date of Issue:2020/12/22 13:49
  • HPLC: What solvents cannot be used in PEEK piping?

    Do not use the solvents listed below as the mobile phase when PEEK tubing is used for plumbing. These solvents degrade the strength of the PEEK resin, which ... Show Detail

    • No:4632
    • Date of Issue:2020/12/22 13:22
  • Sawtooth-shaped noise occurs

    Check whether the noise disappears when solvent delivery stops. Check the solvent delivery flow status (pulsation). If pulsation is large, rinse the flow ch... Show Detail

    • No:4300
    • Date of Issue:2020/12/03 11:06
    • Brached FAQ
  • Cyclic spiky noise is output

    Check whether the noise disappears when solvent delivery stops. Check the solvent delivery flow status (pulsation). If pulsation is large, rinse the flow ch... Show Detail

    • No:4299
    • Date of Issue:2020/12/03 11:05
    • Brached FAQ

1-10 of Total 34

This site uses the FAQ system "PKSHA FAQ", which is a product of PKSHA Technology Inc.