Frequently Referenced FAQ
FAQ within [ HPLC ]
-
«Main Cause» There is a PC data buffer overflow. «Countermeasure» Check the PC status and the cable connections. If the error persists, turn the power OFF ... Show Detail
- No:3646
- Date of Issue:2020/12/02 16:31
- Category: Detector
-
«Main Cause» Error occurred during system check. «Countermeasure» Turn the power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3645
- Date of Issue:2020/12/02 16:31
- Category: Detector
-
«Main Cause» Mobile phase has leaked inside the instrument. «Countermeasure» Check the plumbing. Show Detail
- No:3644
- Date of Issue:2020/12/02 16:30
- Category: Detector
-
«Main Cause» Invalid EEPROM parameter. «Countermeasure» Turn the power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3643
- Date of Issue:2020/12/02 16:30
- Category: Detector
-
Error Code:[0x81F1] WARN : DEGAS PRS
«Main Cause» The abnormality of the vacuum pressure of the on-line degasser connect to this instrument will display for a certain time of time. Check the vac... Show Detail
- No:3642
- Date of Issue:2020/12/02 16:30
- Category: Solvent Delivery Module
-
Error Code:[0x81D3] WARN : M-PHASE
«Main Cause» The remaining volume of mobile phase is less than the alarm level. «Countermeasure» Replacement the mobile phase and reset the mobile phase qua... Show Detail
- No:3641
- Date of Issue:2020/12/02 16:30
- Category: Solvent Delivery Module
-
Error Code:[0x81D2] WARN : M-PHASE
«Main Cause» The remaining volume of mobile phase is less than the alarm level. «Countermeasure» Replacement the mobile phase and reset the mobile phase qua... Show Detail
- No:3640
- Date of Issue:2020/12/02 16:30
- Category: Solvent Delivery Module
-
Error Code:[0x81D1] WARN : M-PHASE
«Main Cause» The remaining volume of mobile phase is less than the alarm level. «Countermeasure» Replacement the mobile phase and reset the mobile phase qua... Show Detail
- No:3639
- Date of Issue:2020/12/02 16:30
- Category: Solvent Delivery Module
-
Error Code:[0x81D0] WARN : M-PHASE
«Main Cause» The remaining volume of mobile phase is less than the alarm level. «Countermeasure» Replacement the mobile phase and reset the mobile phase qua... Show Detail
- No:3638
- Date of Issue:2020/12/02 16:30
- Category: Solvent Delivery Module
-
Error Code:[0x0030] ERROR P.MAX
«Main Cause» The discharge pressure of pump exceeds the Settings [P.Max]. Pumping will automatically stop. However, if "S-PROT" of auxiliary operation is Set... Show Detail
- No:3637
- Date of Issue:2020/12/02 16:30
- Category: Solvent Delivery Module
651-660 of Total 943