Error Code:[0x523F] ERROR PFILE AIR.A VOL
«Main Cause» The liquid volume specified for air intake in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a valu... Show Detail
- No:3944
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5240] ERROR PFILE AIR.A SPEED
«Main Cause» The suction speed specified for air intake in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a valu... Show Detail
- No:3945
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5241] ERROR PFILE MIX POS
«Main Cause» The needle is not positioned inside or above a sample vial when the MIX command is executed in the pretreatment program. «Countermeasure» Add a... Show Detail
- No:3946
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5242] ERROR PFILE MIX COUNT
«Main Cause» The number of repetitions specified by the MIX command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setti... Show Detail
- No:3947
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5243] ERROR PFILE MIX AIR VOL
«Main Cause» The upper/lower air volume specified by the MIX command in the pretreatment program exceeds the setting range. «Countermeasure» Change the sett... Show Detail
- No:3948
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5244] ERROR PFILE MIX VOLUME
«Main Cause» A suction volume specified by the MIX command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a v... Show Detail
- No:3949
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5245] ERROR PFILE MIX A.SPEED
«Main Cause» The suction speed specified by the MIX command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a ... Show Detail
- No:3950
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5246] ERROR PFILE MIX D.SPEED
«Main Cause» The discharge speed specified by the MIX command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to ... Show Detail
- No:3951
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5247] ERROR PFILE APPORT FROM
«Main Cause» The vial number specified by the APPORT command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a... Show Detail
- No:3952
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5248] ERROR PFILE APPORT TO
«Main Cause» The vial number specified by the APPORT command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a... Show Detail
- No:3953
- Date of Issue:2020/12/02 16:44
- Category: Autosampler