Error Code:[0x5203] FATAL NOT CONNECT PLB
«Main Cause» Communication with the measuring pump and low pressure valve control board failed. «Countermeasure» Contact a Shimadzu sales or service represe... Show Detail
- No:3884
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5202] FATAL NOT CONNECT XZ
«Main Cause» Communication with the X-axis and Z-axis motor control board failed. «Countermeasure» Contact a Shimadzu sales or service representative. Show Detail
- No:3883
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5201] FATAL NOT PROTECTED
«Main Cause» The configuration settings failed to be retrieved. «Countermeasure» If an error occurs each time started, contact a Shimadzu sales or service r... Show Detail
- No:3882
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5200] FATAL SYSTEM ERROR
«Main Cause» A system error occurred. «Countermeasure» Switch the power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3881
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x0061] ERROR LEAK DETECTED
«Main Cause» Leakage occurred from a tubing joint or valve gap. «Countermeasure» Check the following locations for leakage. ・If there is leakage from the in... Show Detail
- No:3880
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x0018] ERROR PFILE NOT EXIST
«Main Cause» The pretreatment program size exceeded the limit value (max. 255 bytes per file or 4,096 bytes for the entire program). «Countermeasure» Optimi... Show Detail
- No:3879
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x9117] FATAL INSIDE FAN
«Main Cause» A motor cooling fan rotation problem was detected. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service rep... Show Detail
- No:3878
- Date of Issue:2020/12/02 16:44
- Category: Solvent Delivery Module
-
Error Code:[0x9116] ERROR OPEN DRAIN VALVE
«Main Cause» Solvent delivery was stopped because pressure became high during purging. «Countermeasure» If an error message is displayed during auto-purging... Show Detail
- No:3877
- Date of Issue:2020/12/02 16:44
- Category: Solvent Delivery Module
-
Error Code:[0x9115] WARNING MOBILE PHASE D
«Main Cause» The remaining level of the D mobile phase solution is low. «Countermeasure» Replace the mobile phase and reset the mobile phase quantity. Show Detail
- No:3876
- Date of Issue:2020/12/02 16:44
- Category: Solvent Delivery Module
-
Error Code:[0x9114] WARNING MOBILE PHASE C
«Main Cause» The remaining level of the C mobile phase solution is low. «Countermeasure» Replace the mobile phase and reset the mobile phase quantity. Show Detail
- No:3875
- Date of Issue:2020/12/02 16:43
- Category: Solvent Delivery Module