FAQ - Frequently Asked Questions
- Products Search > HPLC
Keyword Search
HPLC
Frequently Referenced FAQ
FAQ within [ HPLC ]
-
Error Code:[0x8B50] SFE ERR TEMP SENS RM
«Main Cause» Room temperature sensor is abnormal. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu s... Show Detail
- No:3704
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8B90] SFC ERR BPR HOME POS
«Main Cause» Could not detect the home position of the BPR motor. «Countermeasure» Press the (power button) on the instrument to turn the power OFF, and th... Show Detail
- No:3705
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8B91] SFC ERR BPR SLIP
«Main Cause» The BPR motor has slipped. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu sales or s... Show Detail
- No:3706
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8B92] SFC ERR BPR OVERHEAT
«Main Cause» BPR has Over-heated. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu sales or service... Show Detail
- No:3707
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8B93] SFC ERR BPR HEAT LOW
«Main Cause» The BPR heater electrical controller is in error. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contac... Show Detail
- No:3708
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8B94] SFC BPR COVER OPEN
«Main Cause» BPR cover is open. «Countermeasure» Attach the BPR cover securely. Show Detail
- No:3709
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8B95] SFC ERR TEMP SENS
«Main Cause» Lamp housing temperature sensor is open or short-circuit. «Countermeasure» Press the (power button) on the instrument to turn the power OFF an... Show Detail
- No:3710
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8BA0] PUMP HEAD COOLER ERR TEMP SENS
«Main Cause» Pump head temperature sensor is open or short-circuit. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and c... Show Detail
- No:3711
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8BA1] PUMP HEAD COOLER ERR COOLER FAN
«Main Cause» The pump head cooling fan is not rotating correctly. «Countermeasure» If anything is interfering with the fan rotation, turn the power OFF and... Show Detail
- No:3712
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
-
Error Code:[0x8BA2] PUMP HEAD COOLER ERR COOL PUMP
«Main Cause» The coolant pump for cooling the pump head has failed. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and c... Show Detail
- No:3713
- Date of Issue:2020/12/02 16:31
- Category: Supercritical Fluid Chromatograph
351-360 of Total 943