«Main Cause» The line number specified by the GOTO command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a v... Show Detail
- No:3964
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5252] ERROR PFILE GOTO FOR.B
«Main Cause» The GOTO command in the pretreatment program specifies a line number that is within a FOR-NEXT range. «Countermeasure» Revise the line number f... Show Detail
- No:3963
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5251] ERROR PFILE GOTO LOOP
«Main Cause» The row with a command was specified as the line number by the GOTO command in the pretreatment program. «Countermeasure» Revise the line numbe... Show Detail
- No:3962
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x5250] ERROR PFILE GOTO LINE #
«Main Cause» The line number specified by the GOTO command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a v... Show Detail
- No:3961
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x524F] ERROR PFILE GOTO F.SIG
«Main Cause» The file number specified by the GOTO command in the pretreatment program does not include a file header. «Countermeasure» Add more headers. Show Detail
- No:3960
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x524E] ERROR PFILE GOTO FILE #
«Main Cause» The file number specified by the GOTO command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a v... Show Detail
- No:3959
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x524D] ERROR PFILE WAIT.M VAR
«Main Cause» The wait time specified by the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a value within the specif... Show Detail
- No:3958
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x524C] ERROR PFILE NSTRK RANGE
«Main Cause» The needle stroke distance specified by the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a value with... Show Detail
- No:3957
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x524B] ERROR PFILE NSTRK POS
«Main Cause» The needle is not positioned within or above a sample vial. «Countermeasure» Add a VIAL.N or other command to move the needle to the sample vial. Show Detail
- No:3956
- Date of Issue:2020/12/02 16:44
- Category: Autosampler
-
Error Code:[0x524A] ERROR PFILE APPORT SPD
«Main Cause» A suction speed specified by the APPORT command in the pretreatment program exceeds the setting range. «Countermeasure» Change the setting to a... Show Detail
- No:3955
- Date of Issue:2020/12/02 16:44
- Category: Autosampler