FAQ - Frequently Asked Questions
- Products Search > HPLC
Keyword Search
HPLC
Frequently Referenced FAQ
FAQ within [ HPLC ]
-
«Main Cause» Acquisition stopped because the position of the needle in relation to the rack has not been adjusted. «Countermeasure» Adjust the position of t... Show Detail
- No:3454
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The position of the needle in relation to the left side rack has not been adjusted. «Countermeasure» Adjust the position of the nee... Show Detail
- No:3455
- Date of Issue:2020/12/02 16:10
- Last Updated:2022/01/06 09:39
- Category: Autosampler
-
«Main Cause» The position of the needle in relation to the right side rack has not been adjusted. «Countermeasure» Adjust the position of the ne... Show Detail
- No:3456
- Date of Issue:2020/12/02 16:10
- Last Updated:2022/01/06 09:42
- Category: Autosampler
-
«Main Cause» The rack ID is not correct. «Countermeasure» Set the correct rack ID for the rack. Show Detail
- No:3457
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» Racks that have the same ID are set in the autosampler. «Countermeasure» Change the rack ID of either the left or right side rack. Show Detail
- No:3458
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The left side sample cooler temperature adjustment was stopped because the left side rack was not set for more than 30 minutes. «Count... Show Detail
- No:3459
- Date of Issue:2020/12/02 16:10
- Last Updated:2022/01/06 09:43
- Category: Autosampler
-
«Main Cause» The left side sample cooler temperature adjustment was stopped because the right side rack was not set for more than 30 minutes. «Countermeasur... Show Detail
- No:3460
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The sample vial number that is outside of the setting range for the set plate is specified in the sequence. «Countermeasure» Check the sequence... Show Detail
- No:3461
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The autosampler needle X-direction motor has slipped. «Countermeasure» Press the (power switch) to turn the power OFF and contact a Shimadzu sa... Show Detail
- No:3462
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The autosampler needle Y-direction motor has slipped. «Countermeasure» Press the (power switch) to turn the power OFF and contact a Shimadzu sa... Show Detail
- No:3463
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
101-110 of Total 941