«Main Cause» Temperature control is turned off because the autosampler rack R heater has overheated and the thermal fuse has blown. «Countermeasure» Press t... Show Detail
- No:3474
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The leak sensor in the autosampler low pressure valve has detected an abnormal condition. «Countermeasure» Press the (power switch) to turn the... Show Detail
- No:3475
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The leak sensor in the autosampler low pressure valve is malfunctioning. «Countermeasure» Press the (power switch) to turn the power OFF and co... Show Detail
- No:3476
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The leak sensor in the autosampler high pressure valve has detected an abnormal condition. «Countermeasure» Press the (power switch) to turn th... Show Detail
- No:3477
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» The leak sensor in the autosampler high pressure valve is malfunctioning. «Countermeasure» Press the (power switch) to turn the power OFF and c... Show Detail
- No:3478
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» Temperature control is turned off because the temperature sensor in autosampler rack L is malfunctioning. «Countermeasure» Press the (power swi... Show Detail
- No:3479
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» Temperature control is turned off because the temperature sensor in autosampler rack L has detected an abnormal condition. «Countermeasure» Pre... Show Detail
- No:3480
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» Temperature control is turned off because the temperature sensor in autosampler rack R is malfunctioning. «Countermeasure» Press the (power swi... Show Detail
- No:3481
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» Temperature control is turned off because the temperature sensor in autosampler rack R has detected an abnormal condition. «Countermeasure» Pre... Show Detail
- No:3482
- Date of Issue:2020/12/02 16:10
- Category: Autosampler
-
«Main Cause» Temperature control is turned off because the temperature sensor in the autosampler dehumidifier unit is malfunctioning. «Countermeasure» Press... Show Detail
- No:3483
- Date of Issue:2020/12/02 16:10
- Category: Autosampler