(HPLC: Amino Acid Analysis) Shutting Down the System
• For 1 to 2 Days When a series of analyses is complete and similar analyses are scheduled in 1 to 2 days time, replace the solution inside the reaction rea... Show Detail
- No:4959
- Date of Issue:2021/02/08 18:11
- Category: Amino Acid Analysis
-
(HPLC: Amino Acid Analysis) Precautions on Handling the C...
• Parts Number: Na-type 228-18837-91: Analysis Column Shim-pack Amino-Na 228-14206-91: Ammonia Trap Column ISC-30Na • Parts Number: Li-type ... Show Detail
- No:4961
- Date of Issue:2021/02/08 18:08
- Last Updated:2021/02/17 10:02
- Category: Amino Acid Analysis
-
(HPLC: Reducing Sugar Analysis) When not using and rinsin...
Since there are sugars predisposed to forming certain metal ions and weak complexes, this method performs separation of such sugars using packing that is c... Show Detail
- No:4956
- Date of Issue:2021/02/08 14:31
- Category: Reducing Sugar Analysis
-
(HPLC: Reducing Sugar Analysis) When not using and rinsin...
• Parts Number: 228-59512-41: Shim-pack ISA-09 (250 mm x 4.0 mm I.D.) 228-59512-42: Shim-pack ISA-09(G) (50 mm x 4.0 mm I.D.) • Precautions wh... Show Detail
- No:4955
- Date of Issue:2021/02/08 14:31
- Last Updated:2021/02/17 10:01
- Category: Reducing Sugar Analysis
-
(HPLC: Organic Acid Analysis) When not using and rinsing ...
• When the analysis is complete, stop pumps as follows. 1. Set the parameters as follows Pump A: 0.2 mL/min Pump B: 0.2 mL/min CTO: OFF ... Show Detail
- No:4948
- Date of Issue:2021/02/05 15:19
- Category: Organic Acid Analysis
-
(HPLC: Organic Acid Analysis) Precautions on Handling the...
Parts Number: 228-17893-91 Analysis Column,Shim-pack SCR-102H 228-17924-91 Guard Column SCR-102H (A guard column generally withstands approximately 5... Show Detail
- No:4947
- Date of Issue:2021/02/05 15:19
- Category: Organic Acid Analysis
-
(HPLC) Check the Condition of Consumables (System Check)
By executing the system check, you can check the usage of consumables for the entire system. • LCsolution, LabSolutions To open the [System Check... Show Detail
- No:4965
- Date of Issue:2021/02/05 10:54
- Category: Common
-
(HPLC) Non-injection method (Without sample)
LCsolution, LabSolutions, how to do non-injection when the system includes an autosampler. Vial#:Sets the vial No. of the autosampler to be used for dat... Show Detail
- No:4925
- Date of Issue:2021/02/05 10:54
- Last Updated:2021/02/09 08:52
- Category: Common
-
(HPLC) SIL Adjusting the plate position
Adjusting the plate position «ADJUST PLATE» WARNING: Do NOT put your hand inside the autosampler while the instrument is operating. During adjustm... Show Detail
- No:4816
- Date of Issue:2021/01/21 10:28
- Category: Autosampler
- Brached FAQ
-
(HPLC) SIL Setting the distance at which the needle lower...
[PARAMETER] → [NEEDLE STROKE]. or It setting by softwae. This sets the distance at which the needle lowers into a sample vial. Pressing [→] opens a set... Show Detail
- No:4825
- Date of Issue:2021/01/21 10:26
- Category: Autosampler
- Brached FAQ
41-50 of Total 929