(LC Column) General method for washing reversed-phase column
・Flush the solution that elutes the substance adsorbed on the column. Do not precipitate out the salt inside the column. If a salt may have been used, the co... Show Detail
- No:10878
- Date of Issue:2024/09/30 09:32
- Category: LC Columns , LC Columns
-
(LC column) Retention time shifted rapidly when the aqueo...
It is recommended to increase the concentration of organic solvents or use a column that supports 100% aqueous mobile phase. Recommended product: Shim-pack ... Show Detail
- No:10682
- Date of Issue:2024/09/30 09:32
- Category: LC Columns , LC Columns
-
(LC Column) Poor retention time reproducibility in batch ...
->Please check whether the mobile phase is degassed. (Reference:5 Degassing Methods : SHIMADZU (Shimadzu Corporation)) ->Please check whether the pum... Show Detail
- No:10681
- Date of Issue:2024/09/30 09:32
- Category: LC Columns , LC Columns
- Brached FAQ
-
(LC Column) Some peaks have bad shapes.
Repeat the analysis to see if there is any improvement. The column may age and improve. If metal adsorption is suspected, try a filler with less metal ions ... Show Detail
- No:10687
- Date of Issue:2024/09/30 09:31
- Category: LC Columns , LC Columns
- Brached FAQ
-
(FTIR) Consumables (Accessories for attenuated total refl...
(FTIR) Consumables (Accessories for attenuated total reflection measurement) • Attenuated Total Reflection Attachment Appearance • Hrizontal Type ... Show Detail
- No:6345
- Date of Issue:2023/12/07 10:00
- Last Updated:2024/09/30 16:19
- Category: FTIR Spectroscopy(FT-IR) , FTIR Spectroscopy Consumables
-
(FTIR) Consumables (FTIR main unit)
Appearance Click here for Replacement Silica Gels. Show Detail
- No:4899
- Date of Issue:2023/12/07 10:00
- Last Updated:2024/12/26 11:13
- Category: FTIR Spectroscopy(FT-IR) , FTIR Spectroscopy Consumables
-
- No:6916
- Date of Issue:2021/09/06 16:07
- Category: Common , LC Consumables
- Brached FAQ
-
(TOC) Consumables (Carrier Gas Purification Kit)
- No:6656
- Date of Issue:2021/07/27 13:35
- Last Updated:2026/02/19 15:17
- Category: Consumables , TOC Analysis Consumables
-
Appearance Show Detail
- No:6655
- Date of Issue:2021/07/27 13:34
- Last Updated:2024/09/30 16:30
- Category: Consumables , TOC Analysis Consumables
-
Appearance Show Detail
- No:6654
- Date of Issue:2021/07/27 13:31
- Last Updated:2024/09/30 16:31
- Category: Consumables , TOC Analysis Consumables