FAQ - Frequently Asked Questions
- Products Search > Molecular Spectroscopy > FTIR Spectroscopy(FT-IR)
Keyword Search
Frequently Referenced FAQ
FAQ within [ FTIR Spectroscopy(FT-IR) ]
-
(FTIR) Consumables (Accessories for attenuated total refl...
(FTIR) Consumables (Accessories for attenuated total reflection measurement) • Attenuated Total Reflection Attachment Appearance • Hrizontal Type ... Show Detail
- No:6345
- Date of Issue:2023/12/07 10:00
- Last Updated:2024/09/30 16:19
-
(FTIR) Consumables (FTIR main unit)
Appearance Click here for Replacement Silica Gels. Show Detail
- No:4899
- Date of Issue:2023/12/07 10:00
- Last Updated:2024/09/30 16:19
-
(FTIR) The Baseline Fluctuates
In the measurement frequency range of the FTIR, there is a regionin which water vapor and carbon dioxide are absorbed. The baseline fluctuates due to fluctu... Show Detail
- No:8874
- Date of Issue:2022/06/28 15:36
-
(FTIR) Noise Appears at High Absorbance Peak Top
When performing a Fourier transform on a finite interval of data,computational noise is likely to occur due to discontinuities in thedata at both ends, and t... Show Detail
- No:8876
- Date of Issue:2022/06/28 15:36
-
(FTIR) FTIR Analysis Basic Qestion
Click here forFTIR Analysis Basic Qestion. The following Q & A is described. Q: Is FTIR affected by the environment? Q: How deep does the infrared... Show Detail
- No:4913
- Date of Issue:2021/02/02 08:54
-
(FTIR) Suitable Locations and Preparation
Operation guarantee temperature range:10 to 30ºC, within the temperature fluctuation range ±2 ºC/h Installationtemperature range: • IRSpirit / IRXross:... Show Detail
- No:4912
- Date of Issue:2021/01/27 21:40
- Last Updated:2022/06/28 13:44
-
(FTIR) IRTracer-100 Replacement of Beam Splitter Unit
The scan wavenumber range of the IRTracer-100 can be changed by switching the beam splitter unit. If it is expected that the main power supply will be off fo... Show Detail
- No:4911
- Date of Issue:2021/01/27 21:25
-
(FTIR) IRSpirit Wavenumber Calibration
Execute Wavenumber calibration of IRSpirit using peaks of carbon dioxide and water vapor. FTIR spectrum is described with wavenumber unit. Since wavenumber ... Show Detail
- No:4909
- Date of Issue:2021/01/27 20:50
-
(FTIR) Power Spectrum Becomes too Small, or Fluctuates
Reason 1. Deterioration because of long term use 2. Trouble with the power board 3. Trouble with the detector Solution 1. Deterioration becaus... Show Detail
- No:4908
- Date of Issue:2021/01/27 20:30
-
(FTIR) A Part of the Mirror Is a Little White
Reason It seems to be the result of the heat of the infrared light source for an extended time. Solution Conduct the performance check according t... Show Detail
- No:4907
- Date of Issue:2021/01/27 20:30
1-10 of Total 23