FAQ - Frequently Asked Questions
- Products Search > Elemental Analysis
Keyword Search
Frequently Referenced FAQ
FAQ within [ Elemental Analysis ]
-
(EDX) Quantitative analysis with AsKα
Yes, this is possible. The analysis lines (Kα, Lα, etc.)used in quantitative calculations are set in the sensitivity coefficients method files (sysmetal, sy... Show Detail
- No:5669
- Date of Issue:2021/04/28 13:21
- Last Updated:2021/05/20 08:37
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) Analysis of samples containing many elements that c...
In quantitative calculations utilizing the FP method, if the samples contains elements that cannot be detected with the EDX (C (carbon), H (hydrogen), O (oxy... Show Detail
- No:5667
- Date of Issue:2021/04/28 13:20
- Last Updated:2021/05/20 08:36
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) Quantitative calculation of FP method
With the X-ray fluorescence spectrometry, if the composition (elements and content) of the sample is known, X-ray fluorescence intensities can be calculated ... Show Detail
- No:5665
- Date of Issue:2021/04/28 13:18
- Last Updated:2021/05/20 08:34
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) The sample image is faint.
Remedies1: Adjust the light level in the PCEDXNaviwindow. (EDX-LE):Adjust the light level in the [ScreeningAnalysis] window. Remedies2: The sample... Show Detail
- No:5621
- Date of Issue:2021/04/07 10:36
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) The sample has fallen off the beam window into the ...
Removal of the sample, adjustmentand verification of the inside of thespectrometer are necessary. Contacta Shimadzu sales or service representative Show Detail
- No:5620
- Date of Issue:2021/04/07 10:34
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) The sample chamber cover does not open smoothly or ...
Adjustment or part replacement isnecessary. Contact a Shimadzu sales or service representative. Show Detail
- No:5619
- Date of Issue:2021/04/07 10:33
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) An abnormal sound or smell is being produced from t...
Turn the power OFF and unplug theinstrument. Contact a Shimadzu sales or service representative. Show Detail
- No:5618
- Date of Issue:2021/04/07 10:32
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) No spectrum name is identified. The intensity indic...
Check Points:Use the sample for energy calibration,and check if peaks appear at thecorrect positions. Remedies:Perform energy calibration.Perform an energ... Show Detail
- No:5617
- Date of Issue:2021/04/07 10:31
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) Analysis cannot be started. "Unknown" or "Cannot ge...
Check Points1:Check that the power switch of thespectrometer is ON. Remedies1:Turn the power to the spectrometer ONand restart the software. Check ... Show Detail
- No:5616
- Date of Issue:2021/04/07 10:30
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
-
(EDX) The instrument is not turned ON.
Check Points1:Check that the power cable isconnected correctly. Remedies1:Connect the power cable correctly. Check Points2:Check that power is su... Show Detail
- No:5615
- Date of Issue:2021/04/07 10:28
- Category: Energy Dispersive X-ray Fluorescence Spectroscopy(EDX)
81-90 of Total 132