FAQ within [ Elemental Analysis ]
-
(AA) Checking for Leaks of Pressure Regulators (Optional)
WARNING: • If a mistake is made in the piping, it may cause flashback on ignition. • Always set the gas supply pressures at the specified values. • N... Show Detail
- No:5261
- Date of Issue:2021/03/25 10:34
- Category: Atomic Absorption Spectroscopy(AA)
-
A constant check is conducted for gas leakage from the fuel gas tube inside the gas control unit. This section describes the method for inspecting for leaka... Show Detail
- No:5260
- Date of Issue:2021/03/25 10:30
- Last Updated:2022/07/07 10:08
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) Checking the Pilot Flame Unit
With extended use of the instrument, soot may accumulate on the electrode in the pilot flame unit. When sootbuilds up in this area, it may obstruct the pilot... Show Detail
- No:5259
- Date of Issue:2021/03/25 10:24
- Last Updated:2022/07/07 10:04
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) Atomizer Positioning Adjustment
Parts Number:206-52046-91Card (Packet of 10) 1. Select an element that you usually use in the flame continuous method. 2.In the [Optics Parameters] page,... Show Detail
- No:5258
- Date of Issue:2021/03/25 10:20
- Last Updated:2022/07/07 09:50
- Category: Atomic Absorption Spectroscopy(AA)
- Brached FAQ
-
Click here for AA Consumables(Burner Head). WARNING:Immediately after the flame has been extinguished the burner head is hot, so leave it for at least... Show Detail
- No:5256
- Date of Issue:2021/03/25 10:08
- Last Updated:2022/07/07 09:42
- Category: Atomic Absorption Spectroscopy(AA)
- Brached FAQ
-
(AA) Replacing the Hollow Cathode Lamp (AA-7800/7000 series)
Click here for AAConsumables(Hollow cathode lamp). WARNING: • Do NOT touch the terminals of the lamp sockets while the power is on. Be sure to ... Show Detail
- No:5250
- Date of Issue:2021/03/24 11:17
- Last Updated:2022/07/08 09:02
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) Replacing the Deuterium Lamp (AA-7800/7000 series)
Click here for AAConsumables(D2 Lamp) WARNING:Wait at least 30 minutes after turning the D2 lamp off before replacing the lamp.Otherwise you could be ... Show Detail
- No:5249
- Date of Issue:2021/03/24 10:53
- Last Updated:2022/07/08 09:01
- Category: Atomic Absorption Spectroscopy(AA)
-
- No:6491
- Date of Issue:2021/03/23 14:30
- Last Updated:2024/09/30 16:25
- Category: Atomic Absorption Spectroscopy(AA) , Atomic Absorption Spectrophotometer (AA) Consumables
-
(AA) Consumables(Parts for ASC/ASK)
Parts for ASC, ASK Appearance Show Detail
- No:6489
- Date of Issue:2021/03/23 14:26
- Last Updated:2024/09/30 16:26
- Category: Atomic Absorption Spectroscopy(AA) , Atomic Absorption Spectrophotometer (AA) Consumables
-
(AA) Consumables(Parts for Hydride Vapor Generator: HVG-1...
- No:6487
- Date of Issue:2021/03/23 14:25
- Last Updated:2024/09/30 16:28
- Category: Atomic Absorption Spectroscopy(AA) , Atomic Absorption Spectrophotometer (AA) Consumables