(AA) ASC, Nozzle Position Adjustment
1. If the sampler has been installed on the slide, slide the slide to the left side. 2. Set the turntable for use with the flame method. 3. Execute [In... Show Detail
- No:5412
- Date of Issue:2021/03/31 13:39
- Last Updated:2022/07/08 14:34
- Category: Atomic Absorption Spectroscopy(AA)
- Brached FAQ
-
Nozzle ASSY, F is the intake nozzle for flame continuous measurement. Be sure to use this nozzle whenperforming flame continuous measurement. NOTE:Tak... Show Detail
- No:5411
- Date of Issue:2021/03/31 13:26
- Last Updated:2022/07/07 13:18
- Category: Atomic Absorption Spectroscopy(AA)
- Brached FAQ
-
(AA) GFA, Cleaning the Cooling Water Filter (element)
If dirt in the cooling water collects in the filter element, a cooling water error will occur. In this case, use the followingprocedure to clean the filter e... Show Detail
- No:5438
- Date of Issue:2021/03/31 11:55
- Last Updated:2022/07/08 15:38
- Category: Atomic Absorption Spectroscopy(AA)
-
After measurements are repeated many times, the seal (PTFE ring) may be contaminated with soot or smokegenerated from samples. If the contamination becomes s... Show Detail
- No:5437
- Date of Issue:2021/03/31 11:47
- Last Updated:2022/07/08 15:36
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) GFA, Cleaning the Slide Mechanism
The right-hand cooling block moves rightward and leftward along the two guide rods. During the sampleheating, the graphite tube expands, causing the right-ha... Show Detail
- No:5436
- Date of Issue:2021/03/31 11:45
- Last Updated:2022/07/08 15:34
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) GFA, Cleaning the Temperature Sensor
WARNING: The filter is made of glass. Handle carefully to avoid breaking it.Broken glass may cause injuries. When the graphite furnace is heated, the ... Show Detail
- No:5435
- Date of Issue:2021/03/31 11:43
- Last Updated:2022/07/08 15:33
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) GFA, Cleaning and Replacing Procedure for Graphite C...
1. Press the eject arm to release the lock and remove the graphite tube. 2. Pull the window plate sockets out from the cooling blocks. 3. Wipe off soot dep... Show Detail
- No:5434
- Date of Issue:2021/03/31 11:28
- Last Updated:2022/07/08 15:31
- Category: Atomic Absorption Spectroscopy(AA)
- Brached FAQ
-
(AA) GFA, Cleaning the Window Plate Sockets and Window Pl...
WARNING: • RISK OF ELECTRIC SHOCK:Before attaching or detaching the graphite furnace or heating cables, make sure that the power is off. • The window pla... Show Detail
- No:5555
- Date of Issue:2021/03/31 11:10
- Last Updated:2022/07/08 15:37
- Category: Atomic Absorption Spectroscopy(AA)
-
(AA) GFA, Mounting the Graphite Cap and Holder
1. Mount the graphite cap. 2. Press the release lever to release the lock of the furnace and open the right-hand cooling block fully to theright. 3. Insert... Show Detail
- No:5430
- Date of Issue:2021/03/31 10:51
- Last Updated:2022/07/08 15:20
- Category: Atomic Absorption Spectroscopy(AA)
-
Cause1: Deposits have become attached tothe slot in the burner head. Corrective Action1: Wash the burner head.Click here forBurner Maintenance Caus... Show Detail
- No:5315
- Date of Issue:2021/03/26 13:27
- Last Updated:2022/07/07 11:14
- Category: Atomic Absorption Spectroscopy(AA)
101-110 of Total 133