FAQ - Frequently Asked Questions
- Products Search > GC-MS
Keyword Search
Frequently Referenced FAQ
FAQ within [ GC-MS ]
-
(GCMS) Vacuum System Auto Startup Errors
Cause 1: Does Rotary Pump1 (RP1) operate? Action 1: Connect the RP1 power cable to the back panel of the MS, and turn on the RP1 switch. If not resolve... Show Detail
- No:4708
- Date of Issue:2020/12/17 16:03
- Category: Troubleshooting
-
• "Filament consumed" message appears. Filament installation is not correctly. Filament malfunction. Click here for Filament Replacement Procedur... Show Detail
- No:4709
- Date of Issue:2020/12/17 16:18
- Category: Troubleshooting
-
(GCMS) Autotuning and Analysis Errors
1. Error message displayed when standard is introduced. Checks that Filament ON Errors. 2. "Initialization Error" message appears. Whenstandar... Show Detail
- No:4710
- Date of Issue:2020/12/17 16:28
- Category: Troubleshooting
-
(GCMS) No peaks appear, or peaks are too small
Cause 1: Carrier gas flows? Action 1: If carrier gas is not flowing, please let the carrier gas flow. Cause 2: Carrier gas leaks. Action 2: Tigh... Show Detail
- No:4711
- Date of Issue:2020/12/17 16:38
- Category: Troubleshooting
-
(GCMS) "Detector saturated" message appears during analysis
1. Turn on the filament after solvent has completely eluted. If peaks elute before the solvent, use a time program to turn the filament off and on. 2. Dec... Show Detail
- No:4712
- Date of Issue:2020/12/17 16:43
- Category: Troubleshooting
-
(GCMS) RF Temperature Control Error
1. The room temperature might be hight (such as over 40ºC). Check environmental conditions at the installation site. 2. The Q1 or Q3 RF temperature contro... Show Detail
- No:4713
- Date of Issue:2020/12/17 16:46
- Category: Troubleshooting
-
(GCMS) Basic knowledge of GC/MS analysis
Click here for following Basic knowledge of GC/MS analysis. •What does m/z mean? •What are the measurement principles of MS? •Why are there d... Show Detail
- No:4715
- Date of Issue:2020/12/23 11:32
- Category: Setting
-
(GCMS) Starting the Instrument
This section explains how to start up and shut down an installed instrument. For instruments that do not have a CID, skip that section. 1. Turn on ... Show Detail
- No:4756
- Date of Issue:2021/01/12 10:11
- Last Updated:2021/01/12 15:39
- Category: Setting
-
(GCMS) Shutting Down the Instrument
1. Shut down the vacuum system. 1) Click the Assistant Bar [Vacuum Control] icon to open the [Vacuum Control] dialog box. 2) Click the [Auto Shutdo... Show Detail
- No:4758
- Date of Issue:2021/01/12 10:14
- Category: Setting
-
• Injection port septum • Glass inserts (for capillary column) • Glass insert parts • Silica wool Show Detail
- No:6476
- Date of Issue:2021/06/23 17:07
- Last Updated:2023/06/08 14:02
- Category: Maintenance
21-30 of Total 56