FAQ within [ GC-MS ]
-
1. Automatically stop the GC/MS. Wait until the "system shutdown" message appears. 2.Pull the column oven door latch toward you. 3.... Show Detail
- No:7234
- Date of Issue:2020/12/17 10:18
- Category: Maintenance
-
(GCMS) Guard Column Installation
1. Cut the deactivated fused silica tube (guard column) to approx. 2 m. 2. Using the capillary cutter, cut the connecting sections of the guard c... Show Detail
- No:7236
- Date of Issue:2020/12/17 10:18
- Category: Maintenance
-
(GCMS) DI-2010 Operation Methods
Parts Number: 225-04209 CAP(Cap for the DI-2010) 225-09344 SAMPLE VIAL 100 PC (DI-2010 standard accessories (10 pcs):Sample pot made of Pyrex) 225-0... Show Detail
- No:4701
- Date of Issue:2020/12/17 12:45
- Category: Setting
-
(GCMS) Chemical Ionization(CI, NCI) When good spectrum ca...
There may be leak of the reagent gas if the conditionsare not satisfied in spite that the reagent gas is being supplied. The possible causes of leak are desc... Show Detail
- No:4702
- Date of Issue:2020/12/17 12:59
- Category: Troubleshooting
-
(GCMS) Chemical Ionization(CI, NCI) When signal intensit...
Cause 1: Either the cylinder valve of the gas cylinder, the control knob of the pressure regulator, or the outlet valve of the pressure regulator is closed. ... Show Detail
- No:4703
- Date of Issue:2020/12/17 12:59
- Category: Troubleshooting
-
(GCMS) Chemical Ionization(CI, NCI) Reagent Gas Setup Pro...
Parts Number: 225-07776-91 PLUG KIT (Used as a stop cock when no reagent gas is used.) 1. Automatically stop the GC/MS in GCMSsolution. Wait until t... Show Detail
- No:4688
- Date of Issue:2020/12/17 13:08
- Category: Setting
-
(GCMS) Measurres durriing Powerr Outtage
For power outages of 10 minutes or less, normally no particular procedure is required as long as the [Vacuum Restart Mode] checkbox is selected in the window... Show Detail
- No:4704
- Date of Issue:2020/12/17 13:21
- Category: Troubleshooting
-
This section describes how to check the instrument for leaks. If an air leak is clearly present, locate the leak as described in "2. MS Vacuum Leak Check", a... Show Detail
- No:4705
- Date of Issue:2020/12/17 15:41
- Category: Maintenance
-
(GCMS) Error status indicated by LED on MS
Normal LED Indications: Switch MS Unit → All 3 LED light → Green and Red LED goes out → Yellow LED remains ON LED Error Indications Yellow LED... Show Detail
- No:4706
- Date of Issue:2020/12/17 15:49
- Category: Troubleshooting
-
(GCMS) GCMSsolution Software Startup Errors
1. PC and MS or MS and GC connected properly? All connections must be made properly 2. Is GC power on? Turn on GC power supply and restart. 3. Is MS po... Show Detail
- No:4707
- Date of Issue:2020/12/17 15:54
- Category: Troubleshooting