In case of an emergency, such as when the stage does not stop, press the EMERGENCYSTOP switch on the front of the instrument. Inspect the instrument and eli... Show Detail
- No:8590
- Date of Issue:2022/04/25 13:08
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) In an Emergency
In case of an emergency, such as when the stage does not stop, press the EMERGENCYSTOP switch on the front of the instrument to immediately stop the instrume... Show Detail
- No:8615
- Date of Issue:2022/04/25 13:08
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) Handling a Power Outage/Abnormality
The instrument stops when the primary power supply to the instrument is shut off orwhen the supply voltage momentarily drops due to lightning or other causes... Show Detail
- No:8592
- Date of Issue:2022/04/25 14:34
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) Handling a Power Outage/Abnormality
The instrument stops when the primary power supply to the instrument is shut off orwhen the supply voltage momentarily drops due to lightning or other causes... Show Detail
- No:8616
- Date of Issue:2022/04/25 14:34
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) Changing the Administrator Password
The password for changing to administrator mode can be changed. NOTE: • Use this function in administrator mode. Click here for "(SMX-6010) Switchi... Show Detail
- No:8594
- Date of Issue:2022/04/25 15:14
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) Changing the Administrator Password
The password for changing to administrator mode can be changed. NOTE: • Use this function in administrator mode. Click here for "(SMX-1010/1020) Sw... Show Detail
- No:8619
- Date of Issue:2022/04/25 15:14
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) Switching to Administrator Mode
The functions available in the control software differ depending on the user mode. To use functions operated in administrator mode, the administrator passwo... Show Detail
- No:8593
- Date of Issue:2022/04/25 15:15
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) Switching to Administrator Mode
The functions available in the control software differ depending on the user mode. To use functions operated in administrator mode, the administrator passwo... Show Detail
- No:8618
- Date of Issue:2022/04/25 15:15
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) Performing Target Rotation
The X-ray generator irradiates an electron beam on a target in order to generate X-rays. The part of the target where the electron beam strikes (X-ray gener... Show Detail
- No:8597
- Date of Issue:2022/04/28 09:00
- Category: Xslicer SMX-6010
-
(SMX-6010) Adjusting the Filament Value
Filament value adjustment is the operation in which the current that flows through thefilament is adjusted to an optimal value in order to enable the filamen... Show Detail
- No:8598
- Date of Issue:2022/04/28 09:20
- Category: Xslicer SMX-6010