(SMX-225CT) In Case of Emergency
WARNING: In the event of a malfunction or other problem, such as if an unusual odoror smoke is observed, immediately shut off power supply to the system bysw... Show Detail
- No:8660
- Date of Issue:2022/05/18 10:52
- Category: inspeXio SMX-225CT
-
(SMX-1010/1020) Outputting the Instrument Information
Output the information related to the usage status of the instrument. If a problem occurs with the instrument, you may be required to output the instrumenti... Show Detail
- No:8634
- Date of Issue:2022/05/17 09:26
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) Outputting the Instrument Information
Output the information related to the usage status of the instrument. If a problem occurs with the instrument, you may be required to output the instrumenti... Show Detail
- No:8630
- Date of Issue:2022/05/17 09:26
- Last Updated:2022/05/17 09:49
- Category: Xslicer SMX-6010
-
There is a status LED on the right side of the system that displays a three-digit number(Status Code). The status code can display a blinking code, which ... Show Detail
- No:8614
- Date of Issue:2022/04/28 15:00
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) The X-RAY ON/OFF button remains gray and ...
If the condition does notimprove even after performing Action 1 -3,contacta Shimadzu sales or service representative. Cause1: Is the front door comple... Show Detail
- No:8628
- Date of Issue:2022/04/28 14:32
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) The X-RAY ON/OFF button remains gray and X-ray...
If the condition does notimprove even after performing Action 1 -3,contacta Shimadzu sales or service representative. Cause1: Is the front door comple... Show Detail
- No:8613
- Date of Issue:2022/04/28 14:32
- Category: Xslicer SMX-6010
-
(SMX-6010) The X-ray alarm occurs frequently
If the condition does notimprove even after performing Action 1 -3,contact a Shimadzu sales or service representative. Action1:Repeatedly turn X-rays ONan... Show Detail
- No:8612
- Date of Issue:2022/04/28 14:29
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) Exterior Image trouble
Trouble1: No exterior image isdisplayed. Cause1-1: The exterior image cameramay be faulty. Cause1-2: There may be a faultyconnection or disconnectioninsi... Show Detail
- No:8626
- Date of Issue:2022/04/28 14:14
- Category: Xslicer SMX-1010/1020
-
(SMX-6010) Exterior Image trouble
Trouble1: No exterior image isdisplayed. Cause1-1: The exterior image cameramay be faulty. Cause1-2: There may be a faultyconnection or disconnectioninsi... Show Detail
- No:8611
- Date of Issue:2022/04/28 14:14
- Category: Xslicer SMX-6010
-
(SMX-1010/1020) Cross-section images are blurry
Cause1:Is the sample moving duringimage scanning? Action1:Fix the sample in place withtape or other means. Cause2: Cross-section images can beblurr... Show Detail
- No:8625
- Date of Issue:2022/04/28 14:10
- Category: Xslicer SMX-1010/1020