FAQ - Frequently Asked Questions
- Products Search > GC
Keyword Search
Frequently Referenced FAQ
FAQ within [ GC ]
-
Edit the Operation Rights in a Group (LabSolutions DB/CS)
1.Double-click the name of the group to change in the [Rights Group Administration] subwindow,or select the rights group and click [Edit]. 2. Add o... Show Detail
- No:7091
- Date of Issue:2021/10/07 08:51
- Last Updated:2022/01/21 15:08
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
New Rights Groups (LabSolutions DB/CS)
1.Double-click the [User Administration] folder icon in the [Administration Tools] subwindowof the [LabSolutions Main] window. 2.Double click the (Rig... Show Detail
- No:7090
- Date of Issue:2021/10/07 08:36
- Last Updated:2022/01/21 15:07
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
CARm AFC PCB error [Error Code:11 12 53 54]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5870
- Date of Issue:2021/05/18 15:38
- Last Updated:2023/12/13 13:24
- Category: Error/Warning
-
DET#1 2 3 4 PCB error [Error Code:7 8 9 10]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5869
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/07 17:26
- Category: Error/Warning
-
AOCn syringe counter error [Error Code:88 89]
Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer to the following for how to reset the counter value. ... Show Detail
- No:5868
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:23
- Category: Error/Warning
-
CARx insert counter error [Error Code:84 85 86 87]
Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer the below for how to replace the liner. MaintenanceHelp_SPL... Show Detail
- No:5867
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:19
- Category: Error/Warning
-
CARx septum counter error [Error Code:80 81 82 83]
Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer the below for how to replace the septum. MaintenanceHelp_In... Show Detail
- No:5866
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:23
- Category: Error/Warning
-
AUX3-AUX5 relay error [Error Code:1047]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:5865
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:06
- Category: Error/Warning
-
INJ1-DET2 relay error [Error Code:1046]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:5864
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:06
- Category: Error/Warning
-
COL relay error [Error Code:1045]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:5863
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:05
- Category: Error/Warning
31-40 of Total 253