Frequently Referenced FAQ

FAQ within [ Supercritical Fluid Chromatograph ]

11-20 of Total 34

≪ 2 / 4page ≫
  • Error Code:[0x8B93] SFC ERR BPR HEAT LOW

    «Main Cause» The BPR heater electrical controller is in error. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contac... Show Detail

    • No:3708
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B92] SFC ERR BPR OVERHEAT

    «Main Cause» BPR has Over-heated. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu sales or service... Show Detail

    • No:3707
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B91] SFC ERR BPR SLIP

    «Main Cause» The BPR motor has slipped. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu sales or s... Show Detail

    • No:3706
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B90] SFC ERR BPR HOME POS

    «Main Cause» Could not detect the home position of the BPR motor. «Countermeasure» Press the (power button) on the instrument to turn the power OFF, and th... Show Detail

    • No:3705
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B50] SFE ERR TEMP SENS RM

    «Main Cause» Room temperature sensor is abnormal. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu s... Show Detail

    • No:3704
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B49] SFE ERR TEMP SENS VE

    «Main Cause» The vessel thermosensor is abnormal. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu s... Show Detail

    • No:3703
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B48] SFE ERR HEATER TUBE

    «Main Cause» The preheater is abnormal. «Countermeasure» Press the (power button) on the instrument to turn the power OFF and contact a Shimadzu sales or se... Show Detail

    • No:3702
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B47] SFE ERR HEATER H*

    «Main Cause» The extraction pack cell temperature control heater has failed. «Countermeasure» Press the (power button) on the instrument to turn the power O... Show Detail

    • No:3701
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B46] SFE ERR LEAK VESSEL*

    «Main Cause» The temperature of the extraction container has decreased. Check if the extraction pack is tightened. «Countermeasure» Please confirm the extra... Show Detail

    • No:3700
    • Date of Issue:2020/12/02 16:31
  • Error Code:[0x8B45] SFE LOW SET TEMP H*

    «Main Cause» Set temperature value is inappropriate. Temperature is specified with lower than the room temperature plus 5ºC. «Countermeasure» Set temperatur... Show Detail

    • No:3699
    • Date of Issue:2020/12/02 16:31