  • Error Code:[0x910D]

    «Main Cause» The consumable part count data of the pump is corrupted. «Countermeasure» Press the (power switch) to turn the power OFF and contact a Shimadzu... Show Detail

    • No:3547
    • Date of Issue:2020/12/02 16:11
  • Error Code:[0x910C]

    «Main Cause» The backup parameters of the pump are corrupted. «Countermeasure» Press the (power switch) to turn the power OFF and contact a Shimadzu sales o... Show Detail

    • No:3546
    • Date of Issue:2020/12/02 16:11
  • Error Code:[0x9109]

    «Main Cause» The degassing unit is not connected. «Countermeasure» Press the (power switch) to turn the power OFF and contact a Shimadzu sales or service r... Show Detail

    • No:3545
    • Date of Issue:2020/12/02 16:11
  • Error Code:[0x9100]

    «Main Cause» An sealing ability error occurred in the vacuum flow path of the degassing unit. «Countermeasure» Check the vacuum pressure of the degassing un... Show Detail

    • No:3544
    • Date of Issue:2020/12/02 16:11
  • Setting the compressibility of solvent (COMP)

    Although the instrument corrects the compressibility to suppress pulse increase caused by the effect of the compressibility of the solvent, setting a compres... Show Detail

    • No:3013
    • Date of Issue:2020/11/09 15:05
  • Manual Purging the Solvent Delivery Pump

    If adequate purging cannot be achieved with auto-purging or a suction tube does not contain liquid, for example, use the following procedure to manually purg... Show Detail

    • No:3011
    • Date of Issue:2020/11/09 14:29
    • Last Updated:2024/04/11 16:05
  • Maintenance for i-Series(LC-2030/40/50/60) (Video)

    Click here for (LC) Consumables (Suction Filter (Pump)) Click here for (LC) Consumables (Check Valve) Click here for(LC... Show Detail

    • No:4341
    • Date of Issue:2020/08/25 17:34
    • Brached FAQ
  • (LC) Consumables (Suction Filter (Pump))

    Appearance Show Detail

    • No:6597
    • Date of Issue:2020/08/25 13:51
    • Last Updated:2026/07/17 14:46
  • (LC) Consumables (Line Filter)

    Appearance Show Detail

    • No:6594
    • Date of Issue:2020/08/25 13:24
    • Last Updated:2026/07/17 14:49
  • (HPLC) Inspection (Replacement) of Line Filter

    Parts Number:228-35871-99 Line filter UHP 1. Hold the line filter UHP with the provided wrench. 2. Unscrew the male nuts on the end of the SUStub... Show Detail

    • No:5511
    • Date of Issue:2020/08/25 13:19