• Font Size
  • S
  • M
  • L

FAQ within [ Detector ]

71-80 of Total 266

8 / 27page
  • Error Code:[0x5A44]

    «Main Cause» Cannot communicate normally between the instrument and workstation. «Countermeasure» Check the communication environment and operating status b... Show Detail

    • No:4092
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x5A41]

    «Main Cause» Cannot communicate normally between the instrument and workstation. «Countermeasure» Check the communication environment and operating status b... Show Detail

    • No:4091
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x5A21]

    «Main Cause» There is a leak in the detector. «Countermeasure» Inspect the detector leak and wipe up any liquid from around the leak sensor. Show Detail

    • No:4090
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x5A04]

    «Main Cause» Information in the nonvolatile memory could not be read. «Countermeasure» Calibrate the detector (wavelength calibration, absorbance correction... Show Detail

    • No:4089
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x58F7] FATAL MIRROR POSITION

    «Main Cause» Detection of the motor home position failed for the lamp switching mirror control motor. «Countermeasure» Switch the instrument power OFF and c... Show Detail

    • No:4088
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x58F4] WARNING WL CHECK NO GOOD

    «Main Cause» Wavelength accuracy check failed due to either a cell installation error, a wavelength calibration error, or a sample or bubbles contained in... Show Detail

    • No:4087
    • Displayed Date:2020/12/02 16:45
    • Updated DTM:2021/01/20 12:05
  • Error Code:[0x58F3] ERROR CELL MEMORY

    «Main Cause» The cell is not fully connected or the cell memory is not functioning properly. «Countermeasure» Check the cell installation. If that does not ... Show Detail

    • No:4086
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x58F2] FATAL GRATING POSITION

    «Main Cause» Failed to detect the home position for the grating motor. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or serv... Show Detail

    • No:4085
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0x58F1] ERROR D2 LAMP NOT LIT

    «Main Cause» The illumination circuit is not functioning properly. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service ... Show Detail

    • No:4084
    • Displayed Date:2020/12/02 16:45
  • Error Code:[0X58F0] FATAL D2 LAMP NOT LIT

    «Main Cause» The illumination circuit is not functioning properly. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service ... Show Detail

    • No:4083
    • Displayed Date:2020/12/02 16:45

71-80 of Total 266

This site uses the FAQ system "OKBIZ. for FAQ", which is a product of PKSHA Communication Inc.