FAQ - Frequently Asked Questions
- Products Search > HPLC > Autosampler
Keyword Search
Frequently Referenced FAQ
FAQ within [ Autosampler ]
-
«Main Cause» The front panel of the autosampler may not be attached correctly. Alternatively, the sensor that detects the position of the front panel is malf... Show Detail
- No:3487
- Date of Issue:2020/12/02 16:10
-
«Main Cause» Temperature control is turned off because a rotation error was detected in the cooling fan of the autosampler. «Countermeasure» Press the (powe... Show Detail
- No:3488
- Date of Issue:2020/12/02 16:10
-
«Main Cause» A rotation error was detected in the exhaust heat fan at the top of the rear of the instrument. «Countermeasure» Press the (power switch) to tu... Show Detail
- No:3489
- Date of Issue:2020/12/02 16:10
-
«Main Cause» Could not detect the home position of the autosampler high pressure valve. «Countermeasure» Press the (power switch) to turn the power OFF and ... Show Detail
- No:3490
- Date of Issue:2020/12/02 16:10
-
«Main Cause» Teaching has not been executed for the autosampler injection port. «Countermeasure» Adjust the position of the needle in relation t... Show Detail
- No:3491
- Date of Issue:2020/12/02 16:10
- Last Updated:2021/01/19 12:52
-
Error Code:[0x0010] ERR NDLE HOME X
«Main Cause» Move to X (right and left) direction was faulty. «Countermeasure» Check if nothing is stuck in the movable part. If nothing is stuck, contact ... Show Detail
- No:3557
- Date of Issue:2020/12/02 16:30
-
Error Code:[0x0011] ERR NDLE HOME Y
«Main Cause» Move to Y (front and back) direction was faulty. «Countermeasure» Check if nothing is stuck in the movable part. If nothing is stuck, contact ... Show Detail
- No:3558
- Date of Issue:2020/12/02 16:30
-
Error Code:[0x0012] ERR NDLE HOME Z
«Main Cause» Move to Z (up and down) direction was faulty. «Countermeasure» Check if nothing is stuck in the movable part. If nothing is stuck, contact a S... Show Detail
- No:3559
- Date of Issue:2020/12/02 16:30
-
Error Code:[0x0013] ERR HPV HOME
«Main Cause» Rotation of 6-port valve motor was faulty. «Countermeasure» Remedy this problem referring to the following procedure. (1) Check if the rotor ... Show Detail
- No:3560
- Date of Issue:2020/12/02 16:30
-
Error Code:[0x0014] SIL:NO 3-PORT VALVE HOME
«Main Cause» Rotation of 3-way valve motor was faulty. «Countermeasure» Please perform actions using the following procedures. (1) Check that the rotor sea... Show Detail
- No:3561
- Date of Issue:2020/12/02 16:30
51-60 of Total 297