      Error Code:[0x0013] ERR HPV HOME «Main Cause» Rotation of 6-port valve motor was faulty. «Countermeasure» Remedy this problem referring to the following procedure. (1) Check if the rotor ... Show Detail - No:3560
- Date of Issue:2020/12/02 16:30
 
- 
      Error Code:[0x0012] ERR NDLE HOME Z «Main Cause» Move to Z (up and down) direction was faulty. «Countermeasure» Check if nothing is stuck in the movable part. If nothing is stuck, contact a S... Show Detail - No:3559
- Date of Issue:2020/12/02 16:30
 
- 
      Error Code:[0x0011] ERR NDLE HOME Y «Main Cause» Move to Y (front and back) direction was faulty. «Countermeasure» Check if nothing is stuck in the movable part. If nothing is stuck, contact ... Show Detail - No:3558
- Date of Issue:2020/12/02 16:30
 
- 
      Error Code:[0x0010] ERR NDLE HOME X «Main Cause» Move to X (right and left) direction was faulty. «Countermeasure» Check if nothing is stuck in the movable part. If nothing is stuck, contact ... Show Detail - No:3557
- Date of Issue:2020/12/02 16:30
 
- 
      
      «Main Cause» Teaching has not been executed for the autosampler injection port. «Countermeasure» Adjust the position of the needle in relation t... Show Detail - No:3491
- Date of Issue:2020/12/02 16:10
- Last Updated:2021/01/19 12:52
 
- 
      
      «Main Cause» Could not detect the home position of the autosampler high pressure valve. «Countermeasure» Press the (power switch) to turn the power OFF and ... Show Detail - No:3490
- Date of Issue:2020/12/02 16:10
 
- 
      
      «Main Cause» A rotation error was detected in the exhaust heat fan at the top of the rear of the instrument. «Countermeasure» Press the (power switch) to tu... Show Detail - No:3489
- Date of Issue:2020/12/02 16:10
 
- 
      
      «Main Cause» Temperature control is turned off because a rotation error was detected in the cooling fan of the autosampler. «Countermeasure» Press the (powe... Show Detail - No:3488
- Date of Issue:2020/12/02 16:10
 
- 
      
      «Main Cause» The front panel of the autosampler may not be attached correctly. Alternatively, the sensor that detects the position of the front panel is malf... Show Detail - No:3487
- Date of Issue:2020/12/02 16:10
 
- 
      
      «Main Cause» The consumable part count data for the autosampler and column oven is corrupted. «Countermeasure» Press the (power switch) to turn the power OF... Show Detail - No:3486
- Date of Issue:2020/12/02 16:10
 