Frequently Referenced FAQ

FAQ within [ Autosampler ]

201-210 of Total 297

21 / 30page
  • Error Code:[0x85D4] ERR HAND HOME R

    «Main Cause» Motor's R-axis movement (i.e., rotating the rack) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service represe... Show Detail

    • No:3609
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D3] ERR HAND HOME X

    «Main Cause» Motor's X-axis movement (i.e., taking out the rack) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service repre... Show Detail

    • No:3608
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D2] ERR RC SLIP Y

    «Main Cause» Motor's Y-axis movement (forward/backward) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3607
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D1] ERR RC SLIP Z

    «Main Cause» Motor's Z-axis movement (up/down) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3606
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D0] ERR RC SLIP X

    «Main Cause» Motor's X-axis movement (i.e., taking out the rack) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service repre... Show Detail

    • No:3605
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x8569] NDLE PROTECTED

    «Main Cause» A foreign substance was detected at the tip of the needle. «Countermeasure» Check for foreign substances inside the Autosampler. Show Detail

    • No:3604
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x8566] ERR HEATER

    «Main Cause» There is an error in the sample cooler's heating unit. «Countermeasure» Turn the power OFF and contact a Shimadzu sales or service representat... Show Detail

    • No:3603
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x8564] ERR SLIP Y

    «Main Cause» Needle's Y-axis (forward/backward) movement is incorrect. «Countermeasure» Turn the power OFF and contact a Shimadzu sales or service represen... Show Detail

    • No:3602
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x8563] ERR SLIP X

    «Main Cause» Needle's X-axis (sideways) movement is incorrect. «Countermeasure» Turn the power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3601
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x8551] ERR LEAK DETECT

    «Main Cause» (1) Leak sensor was detected leakage. (2) Sensor is too sensitive. «Countermeasure» (1) Inspect the leakage from the flow line. Wipe out spille... Show Detail

    • No:3600
    • Date of Issue:2020/12/02 16:30