Error Code:[0x5200] FATAL SYSTEM ERROR
«Main Cause» A system error occurred. «Countermeasure» Switch the power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3881
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5201] FATAL NOT PROTECTED
«Main Cause» The configuration settings failed to be retrieved. «Countermeasure» If an error occurs each time started, contact a Shimadzu sales or service r... Show Detail
- No:3882
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5202] FATAL NOT CONNECT XZ
«Main Cause» Communication with the X-axis and Z-axis motor control board failed. «Countermeasure» Contact a Shimadzu sales or service representative. Show Detail
- No:3883
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5203] FATAL NOT CONNECT PLB
«Main Cause» Communication with the measuring pump and low pressure valve control board failed. «Countermeasure» Contact a Shimadzu sales or service represe... Show Detail
- No:3884
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5204] FATAL NOT CONNECT SENS
«Main Cause» Communication with the plate reading board failed. «Countermeasure» Contact a Shimadzu sales or service representative. Show Detail
- No:3885
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5205] ERROR X HOME POSITION
«Main Cause» Something is obstructing the needle's line of movement or there is a mechanical problem in the drive unit. «Countermeasure» Check for any obstr... Show Detail
- No:3886
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5206] ERROR X SLIP
«Main Cause» Something is obstructing the X-direction (left-right) line of movement or there is a mechanical problem in the drive unit. «Countermeasure» Che... Show Detail
- No:3887
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5207] ERROR Y HOME POSITION
«Main Cause» Something is obstructing the needle's line of movement or there is a mechanical problem in the drive unit. «Countermeasure» Check for any obstr... Show Detail
- No:3888
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5208] ERROR Y SLIP
«Main Cause» Something is obstructing the Y-direction (front-rear) line of movement or there is a mechanical problem in the drive unit. «Countermeasure» Che... Show Detail
- No:3889
- Date of Issue:2020/12/02 16:44
-
Error Code:[0x5209] FATAL Z HOME POSITION
«Main Cause» Something is obstructing the needle's line of movement or there is a mechanical problem in the drive unit. «Countermeasure» Check for any obstr... Show Detail
- No:3890
- Date of Issue:2020/12/02 16:44