• Font Size
  • S
  • M
  • L

FAQ within [ Autosampler ]

91-100 of Total 297

10 / 30page
  • Error Code:[0x8566] ERR HEATER

    «Main Cause» There is an error in the sample cooler's heating unit. «Countermeasure» Turn the power OFF and contact a Shimadzu sales or service representat... Show Detail

    • No:3603
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x8569] NDLE PROTECTED

    «Main Cause» A foreign substance was detected at the tip of the needle. «Countermeasure» Check for foreign substances inside the Autosampler. Show Detail

    • No:3604
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D0] ERR RC SLIP X

    «Main Cause» Motor's X-axis movement (i.e., taking out the rack) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service repre... Show Detail

    • No:3605
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D1] ERR RC SLIP Z

    «Main Cause» Motor's Z-axis movement (up/down) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3606
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D2] ERR RC SLIP Y

    «Main Cause» Motor's Y-axis movement (forward/backward) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3607
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D3] ERR HAND HOME X

    «Main Cause» Motor's X-axis movement (i.e., taking out the rack) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service repre... Show Detail

    • No:3608
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D4] ERR HAND HOME R

    «Main Cause» Motor's R-axis movement (i.e., rotating the rack) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service represe... Show Detail

    • No:3609
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D5] ERR HAND HOME Z

    «Main Cause» Motor's Z-axis movement (i.e., moving the rack vertically) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or servic... Show Detail

    • No:3610
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D6] ERR HAND HOME Y

    «Main Cause» Motor's Y-axis movement (forward/backward) is incorrect. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3611
    • Date of Issue:2020/12/02 16:30
  • Error Code:[0x85D9] ERR RELEASE RACK

    «Main Cause» Rack was not released correctly. «Countermeasure» Turn power OFF and contact a Shimadzu sales or service representative. Show Detail

    • No:3612
    • Date of Issue:2020/12/02 16:30

91-100 of Total 297

This site uses the FAQ system "PKSHA FAQ", which is a product of PKSHA Communication Inc.