FAQ - Frequently Asked Questions
- Products Search > HPLC > Autosampler
Keyword Search
Frequently Referenced FAQ
FAQ within [ Autosampler ]
- 
      Error Code:[0x529A] FATAL SUB HEATER «Main Cause» The sub-heater cannot be controlled. «Countermeasure» Turn off the instrument and contact our sales office / distributor or our designated ... Show Detail - No:11660
- Date of Issue:2025/05/27 15:25
- Last Updated:2025/05/28 10:00
 
- 
      (LC) Consumables (Needle(SIL)) Appearance Show Detail - No:11564
- Date of Issue:2025/01/28 10:54
- Last Updated:2025/01/29 14:01
 
- 
      (HPLC) SIL Adjusting the plate position Adjusting the plate position «ADJUST PLATE» WARNING: Do NOT put your hand inside the autosampler while the instrument is operating. During adjustm... Show Detail - No:4816
- Date of Issue:2021/01/21 10:28
- Brached FAQ
 
- 
      (HPLC) SIL Setting the distance at which the needle lower... [PARAMETER] → [NEEDLE STROKE]. or It setting by softwae. This sets the distance at which the needle lowers into a sample vial. Pressing [→] opens a set... Show Detail - No:4825
- Date of Issue:2021/01/21 10:26
- Brached FAQ
 
- 
      (HPLC) Autosampler Adjusting the injection port position Adjusting the injection port position «ADJUST INJ. P» WARINING: Do NOT put your hand inside the autosampler while the instrument is operating. Dur... Show Detail - No:4804
- Date of Issue:2021/01/19 12:51
- Brached FAQ
 
- 
      HPLC: When hexane is used in the rinse solution of the au... When using a rinsing liquid with a hydrocarbon solvent such as hexane as the main component, suction problems can occur irregularly. When such a problem o... Show Detail - No:4630
- Date of Issue:2020/12/22 13:09
 
- 
      (LC) Moving the needle position<ZHOME> Used when the instrument is not to be used for a long time or before moving the instrument. [CONTROL] - [ZHOME] or Pressing directly moves from ... Show Detail - No:4476
- Date of Issue:2020/12/07 12:55
 
- 
      Replacement of Outlet Tubing (HPLC) Parts Number: 228-53184-91 SUS tubing HP OUT(0.1 × 600) (For CTO-20A/20AC) Parts Number: 228-53881-42 Preheart block 30AS(0.1 × 800) (For CTO-30AS) ... Show Detail - No:4763
- Date of Issue:2020/12/04 16:01
- Brached FAQ
 
- 
      Replacement of HPV Rotor and Stator (HPLC) 1. Fill the mobile phase A flow line with an organic solvent such as 2-propanol, methanol, or acetonitrile. NOTE: After the high-pressure valve rotor and s... Show Detail - No:4481
- Date of Issue:2020/12/04 16:01
- Last Updated:2021/07/12 11:35
- Brached FAQ
 
- 
      Replacement of LPV Rotor and Stator (HPLC) Parts Number · LC-2030/2050 228-36923: LPV rotor 228-36917-01: LPV stator · LC-2040/2060 228-71780-48: LPV rotor 6P 228-58668-01: LPV stator 6P... Show Detail - No:4480
- Date of Issue:2020/12/04 16:01
- Brached FAQ
 
1-10 of Total 299