DET#n ignition failed. [Error Code:4203 4204 4205 4206]
Inspect the FID jet according to the following manual. MaintenanceHelp_FID-Collector-Inspection-n-Jet-Replacement.pdf Press(HOME) - [Detector] button on... Show Detail
- No:5926
- Date of Issue:2021/05/18 15:36
- Category: Error/Warning
- Brached FAQ
-
Ignition finished(retried) [Error Code:9011]
Check the following items. ・Check for gas leaks. ・Verify the gas flows. ・Diagnoseignition pulse and ignition sequence by standard ... Show Detail
- No:5925
- Date of Issue:2021/05/18 15:36
- Category: Error/Warning
-
xxx sensor use time warning [Error Code:9012 9013 9014 90...
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5924
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/12 01:49
- Category: Error/Warning
-
CARm is not controlled [Error Code:2141 2142 2143 2213]
Turn on the carrier gas control or remove unused carrier gas line from the analytical line. How to set Flow control [On/OFF] Press (HOME) - [Injection ... Show Detail
- No:5923
- Date of Issue:2021/05/18 15:36
- Last Updated:2023/12/13 13:23
- Category: Error/Warning
-
xxx temperature exceeds the limit [Error Code:1002 1003 1...
Please follow the steps below; Press [Ignore] to close the error dialog. Change the maximum temperature value. Screen_Max-Temperature.pdf ... Show Detail
- No:5922
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/12 01:29
- Category: Error/Warning
-
Gas Selector# sub set point not reached [Error Code:2350 ...
Check whether gas is supplied and whether gas is not leaking from connections. Gas leaks may be occurring in several locations (other than displayed site). Show Detail
- No:5921
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/12 01:29
- Category: Error/Warning
-
Transmission file error[Error Code:4008]
For Ethernet connection, replace the LAN cable. Show Detail
- No:5989
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 14:57
- Category: Error/Warning
-
Transmission port is shut down[Error Code:4007]
For Ethernet connection, replace the LAN cable. Show Detail
- No:5988
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 14:56
- Category: Error/Warning
-
Param by TRS is out of range[Error Code:4006]
For Ethernet connection, replace the LAN cable. Show Detail
- No:5987
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 14:55
- Category: Error/Warning
-
Command is invalid[Error Code:4005]
For Ethernet connection, replace the LAN cable. Show Detail
- No:5986
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 14:53
- Category: Error/Warning