FAQ - Frequently Asked Questions
- Products Search > GC
Keyword Search
Frequently Referenced FAQ
FAQ within [ GC ]
-
SCD nitrogen was overpressure[Error Code:6168]
・Check that the gas supply pressure is within the range below. ・If the gas supply pressure is appropriate, turn off the main power of the inst... Show Detail
- No:5971
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 12:53
- Category: Error/Warning
-
SCD furnace oxygen control irregularity[Error Code:6171]
・Check that the oxygen gas supply pressure is within the range below. ・Check that the gas supply pressure is stable. ・If the error appears re... Show Detail
- No:5972
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 13:29
- Category: Error/Warning
-
SCD furnace oxygen was overpressure[Error Code:6172]
・Check that the gas supply pressure is within the range below. ・If the gas supply pressure is appropriate, turn off the main power of the inst... Show Detail
- No:5973
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 13:32
- Category: Error/Warning
-
SCD ozone source oxygen control irregularity[Error Code:6...
・Check that the oxygen gas supply pressure is within the range below. ・Check that the gas supply pressure is stable. ・If the error appears re... Show Detail
- No:5974
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 13:37
- Category: Error/Warning
-
SCD ozone source oxygen was overpressure[Error Code:6176]
・Check that the gas supply pressure is within the range below. ・If the gas supply pressure is appropriate, turn off the main power of the inst... Show Detail
- No:5975
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 13:42
- Category: Error/Warning
-
DET#4 SCD overcurrent detected[Error Code:6181]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:5976
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 13:45
- Category: Error/Warning
-
DetAPCn hydrogen valve not completely closed[Error Code:2...
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:5977
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 13:48
- Category: Error/Warning
-
DetAPCn ECDG control irregularity[Error Code:2164 2165 21...
・Check that the ECD detector gas supply pressure is within the range below. ・Check that the supply pressure is sufficient for the ECD detector... Show Detail
- No:5978
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/18 15:28
- Category: Error/Warning
-
DetAPCn ECDG valve not completely closed[Error Code:2160 ...
Close the knob of the bypass unit of ECD totally with the ECD gas flow set off. Then, check whether the ECD gas flow on the monitor decreases. When the ECD ... Show Detail
- No:5979
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 14:01
- Category: Error/Warning
-
DetAPCn ECDG set point not reached[Error Code:2156 2157 2...
・Check that the gas main valve is open. ・Check that the gas supply pressure is within the range below. ・Check that the supply pressure is suf... Show Detail
- No:5980
- Date of Issue:2021/05/18 15:35
- Last Updated:2021/06/04 14:32
- Category: Error/Warning
51-60 of Total 255