FAQ - Frequently Asked Questions
- Products Search > GC
Keyword Search
Frequently Referenced FAQ
FAQ within [ GC ]
-
(GC) Consumables (Capillary Column Connector)
• Capillary Column Connector (ClickTek)(Click) Appearance • Capillary Column Connector (Nut and Ferrule) (Click) ... Show Detail
- No:6553
- Date of Issue:2021/07/08 13:47
- Last Updated:2023/06/19 16:34
- Category: Consumables
-
(GC) Consumables (Glass Insert)
• Glass Insert for Capillary Column(Click) • Glass Insert for OCI / PTV(Click) • Glass Insert for Packed Column(Click) • Connecting Part... Show Detail
- No:6550
- Date of Issue:2021/07/08 13:08
- Last Updated:2024/07/04 15:19
- Category: Consumables
-
(GC) Consumables (Injection Port Septa)
A low-bleed septum is not completely free of bleeding. The type of bleeding that occurs varies with the septum and results in different patterns on chromat... Show Detail
- No:6547
- Date of Issue:2021/07/08 12:43
- Last Updated:2024/02/29 08:54
- Category: Consumables
-
(PAC) Consumables (Chromatopac Recording paper)
- No:6545
- Date of Issue:2021/07/08 09:44
- Last Updated:2023/06/20 11:00
- Category: Consumables
-
(GC) Consumables (Shimadzu Super-Clean Gas Filter)
- No:6542
- Date of Issue:2021/07/08 09:25
- Last Updated:2023/06/16 14:54
- Category: Consumables
-
Syringe Selection Guide If a syringe is being used by hand, a manual syringe should be selected. If a syringe is installed in an AOC autosampler, then cho... Show Detail
- No:6518
- Date of Issue:2021/07/01 13:05
- Category: Consumables
-
CARm AFC PCB error [Error Code:11 12 53 54]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5870
- Date of Issue:2021/05/18 15:38
- Last Updated:2023/12/13 13:24
- Category: Error/Warning
-
DET#1 2 3 4 PCB error [Error Code:7 8 9 10]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5869
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/07 17:26
- Category: Error/Warning
-
AOCn syringe counter error [Error Code:88 89]
Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer to the following for how to reset the counter value. ... Show Detail
- No:5868
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:23
- Category: Error/Warning
-
CARx insert counter error [Error Code:84 85 86 87]
Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer the below for how to replace the liner. MaintenanceHelp_SPL... Show Detail
- No:5867
- Date of Issue:2021/05/18 15:38
- Last Updated:2021/06/04 13:19
- Category: Error/Warning
31-40 of Total 257