FAQ - Frequently Asked Questions
- Products Search > GC
Keyword Search
Frequently Referenced FAQ
FAQ within [ GC ]
-
DetAPCn DCG was overpressure[Error Code:2264 2265 2266 2267]
Do not open or close the main valve of the supply gas during APC operation. Restart the GC with the gas supplied. Check that the BID gas supply pressure ... Show Detail
- No:6014
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/03 11:34
- Category: Error/Warning
-
DetAPCn ECDG was overpressure[Error Code:2268 2269 2270 2...
Do not open or close the main valve of the supply gas during APC operation. Restart the GC with the gas supplied. Check that the ECD gas supply pressure ... Show Detail
- No:6015
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/03 11:40
- Category: Error/Warning
-
APCx was overpressure[Error Code:2234 2235 2236 2237 2238...
Do not open or close the main valve of the supply gas during AUX-APC operation. Restart the GC with the gas supplied. Check that the gas supply pressure ... Show Detail
- No:6016
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/03 11:48
- Category: Error/Warning
-
CARx prim is out of range[Error Code:2138 2139 2140 2212]
Check that the carrier gas supply pressure is within the primary pressure range in the configuration described below. Screen_Other-Configuration.pdf ... Show Detail
- No:6017
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/03 11:51
- Category: Error/Warning
-
DetAPCn DCG valve not completely closed[Error Code:2148 2...
Close the knob of the bypass unit of BID totally with the BID DCG flow set off. Then, check whether the BID DCG flow on the monitor decreases. When the BID D... Show Detail
- No:6018
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/03 11:56
- Category: Error/Warning
-
DetAPCn DCG control irregularity[Error Code:2152 2153 215...
Check that the BID detector gas supply pressure is within the range below. Check that the supply pressure is sufficient for the BID detector gas to flow. ... Show Detail
- No:6019
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/07/06 08:11
- Category: Error/Warning
-
APCn hydrogen flowing over the specified value[Error Code...
Do not open or close the main valve of the supply gas during APC operation. Restart the GC with the gas supplied. Check that the hydrogen gas supply pres... Show Detail
- No:6020
- Date of Issue:2021/05/18 15:36
- Last Updated:2021/06/03 12:09
- Category: Error/Warning
-
DetAPCn PCB error [Error Code:13 14 15 16]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5871
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/04 13:33
- Category: Error/Warning
-
APCa-b PCB error [Error Code:23 24 25 26 27 28]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5872
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/04 13:34
- Category: Error/Warning
-
DET#1 2 3 4 FPD overcurrent detected [Error Code:4125 412...
Ensure that strong light does not leak in photomultiplier current from the connection. If the error cannot be resolved after you cut off the light with blac... Show Detail
- No:5873
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/04 14:08
- Category: Error/Warning
121-130 of Total 255