FAQ - Frequently Asked Questions
- Products Search > GC
Keyword Search
Frequently Referenced FAQ
FAQ within [ GC ]
-
SCD PSU-24V error [Error Code:6124]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5906
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:54
- Category: Error/Warning
-
Gas Selector# PCB error [Error Code:91 92]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5905
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:53
- Category: Error/Warning
-
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5904
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:52
- Category: Error/Warning
-
Hydrogen sensor init error [Error Code:77]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5903
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:45
- Category: Error/Warning
-
Atm. press is out of range [Error Code:6]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5902
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:44
- Category: Error/Warning
-
Room temperature is out of range [Error Code:5]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5901
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:43
- Category: Error/Warning
-
DC24V is out of range [Error Code:2]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5900
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:42
- Category: Error/Warning
-
DC5V is out of range [Error Code:1]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5899
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:41
- Category: Error/Warning
-
Clock is initialized [Error Code:29]
Battery for the clock is depleted or the hardware fails. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service ... Show Detail
- No:5898
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:40
- Category: Error/Warning
-
COL A/D converter error [Error Code:30]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5897
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:39
- Category: Error/Warning
91-100 of Total 253