FAQ - Frequently Asked Questions
- Products Search > HPLC > Common
Keyword Search
Frequently Referenced FAQ
FAQ within [ Common ]
-
(LC) Consumables (Flow Line Switching Valve (FCV))
Appearance Appearance Show Detail
- No:6586
- Date of Issue:2020/09/01 15:26
- Brached FAQ
-
Baseline stability is dependent on the flowrate, detector, and mobile phase. Therefore, select a mixer that is appropriate for given system configuration and... Show Detail
- No:3012
- Date of Issue:2020/11/09 14:46
-
Rinse the instrument flow channels with purified or distilled water after pumping a buffer solution. If no analyses will be performed for a while, rinse and... Show Detail
- No:3023
- Date of Issue:2020/11/10 14:22
-
LAN communication confirmation method
You can check the LAN communication between the PC and the instruments by the following method. 1. Right-click on the (Start) menu and select [Run...]... Show Detail
- No:3024
- Date of Issue:2020/11/10 14:41
-
Initial IP address, Log in ID, Pass word (HPLC)
· Instruments [CALIBRATION] menu PW: 00000 · CBM-20(lite)/40(lite), SCL-40 IP address: 192.168.200.99 Sub-net mask: 255.255.255.0 Web contro... Show Detail
- No:4395
- Date of Issue:2020/11/11 10:50
-
Error Code:[0x5F00] ERROR UNUSABLE PANEL
«Main Cause» Communication failed between the operation panel and the main unit. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sal... Show Detail
- No:3850
- Date of Issue:2020/12/02 16:43
-
Error Code:[0x5F01] WARNING BACKUP DATA
«Main Cause» Backup data cannot be loaded from the main unit. «Countermeasure» The system can continue to be operated as it is, but functionality for backin... Show Detail
- No:3851
- Date of Issue:2020/12/02 16:43
-
Error Code:[0x5F02] WARNING NO PAIRING
«Main Cause» Default settings were not set after operation panel replacement. «Countermeasure» The system can continue to be operated as it is, but the inst... Show Detail
- No:3852
- Date of Issue:2020/12/02 16:43
-
Error Code:[0x5F03] FATAL CALIBRATION DATA
«Main Cause» Data was initialized because the saved calibration data was incorrect. «Countermeasure» Instrument performance might be affected. Contact a Shi... Show Detail
- No:3853
- Date of Issue:2020/12/02 16:43
-
Error Code:[0x5F04] FATAL USER DATA
«Main Cause» Data was initialized because the saved user data was incorrect. «Countermeasure» Instrument performance is not affected, but double-check respe... Show Detail
- No:3854
- Date of Issue:2020/12/02 16:43
1-10 of Total 34