FAQ - Frequently Asked Questions
- Products Search > HPLC
Keyword Search
HPLC
Frequently Referenced FAQ
FAQ within [ HPLC ]
-
Cleaning the Interior of the ELSD
1. Set the temperature to 100°C and flow gas at 350kPa. 2.Pump a suitable mobile phase at 2mL/min. CAUTION: Select a mobile phase in which the analyzed s... Show Detail
- No:3073
- Date of Issue:2020/11/11 09:54
- Last Updated:2021/01/07 16:32
- Category: Detector
-
Initial IP address, Log in ID, Pass word (HPLC)
· Instruments [CALIBRATION] menu PW: 00000 · CBM-20(lite)/40(lite), SCL-40 IP address: 192.168.200.99 Sub-net mask: 255.255.255.0 Web contro... Show Detail
- No:4395
- Date of Issue:2020/11/11 10:50
- Category: Common , Detector , System Controller
-
Error Code:[0x5620] FATAL ROM FAILURE
«Main Cause» A system error occurred. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3386
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5621] FATAL RAM FAILURE
«Main Cause» A system error occurred. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3387
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5622] FATAL THERMAL FUSE
«Main Cause» A broken circuit may have occurred in the thermal fuse. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or servic... Show Detail
- No:3388
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5623] FATAL INSIDE FAN
«Main Cause» The fan inside the compartment may have stopped. «Countermeasure» If tubing or other foreign matter is obstructing fan rotation, switch the ins... Show Detail
- No:3389
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5624] FATAL OVEN TEMP SENSOR H
«Main Cause» A broken or short circuit may have occurred in the temperature sensor. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu ... Show Detail
- No:3390
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5625] FATAL OVEN TEMP SENSOR L
«Main Cause» A broken or short circuit may have occurred in the temperature sensor. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu ... Show Detail
- No:3391
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5626] FATAL GAS SENSOR
«Main Cause» A broken circuit may have occurred in the gas sensor. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service ... Show Detail
- No:3392
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
-
Error Code:[0x5627] FATAL AC HEATER
«Main Cause» The heater is not functioning properly. «Countermeasure» Switch the instrument power OFF and contact a Shimadzu sales or service representative. Show Detail
- No:3393
- Date of Issue:2020/12/02 15:47
- Category: Column Oven
31-40 of Total 929