• Font Size
  • S
  • M
  • L

FAQ within [ EHF Series ]

21-28 of Total 28

3 / 3page
  • (EHF) The crosshead descends

    WARNING: Be sure to power off the entire system before performing any operation. Do not work while the power is on. Failure to do so may result in electric... Show Detail

    • No:7591
    • Date of Issue:2021/12/07 10:15
  • (EHF) Crosshead does not descend

    WARNING: Be sure to power off the entire system before performing any operation. Do not work while the power is on. Failure to do so may result in electric... Show Detail

    • No:7589
    • Date of Issue:2021/12/07 10:15
    • Last Updated:2022/01/13 09:18
  • (EHF) Crosshead does not rise

    WARNING: Be sure to power off the entire system before performing any operation. Do not work while the power is on. Failure to do so may result in electric... Show Detail

    • No:7588
    • Date of Issue:2021/12/07 10:15
  • (EHF) Charging the accumulator with nitrogen gas

    The accumulator is filled with nitrogen gas by our company Field Engineer. However, if you purchase the gas charging assembly (Options), you can work on it y... Show Detail

    • No:7587
    • Date of Issue:2021/12/07 10:15
  • (EHF) Checking the crosshead clamp

    1) Check that the crosshead drop prevention stopper is firmly fixed by pushing against the upper surface of the cylinder of the lifting jack. 2) Start the H... Show Detail

    • No:7586
    • Date of Issue:2021/12/07 10:15
  • (EHF) Handling of bolts

    This product uses a hexagon socket head cap screw of Strength Classification 12.9 (10.9 for M24 and above) (except for some parts). Each bolt must be properl... Show Detail

    • No:7585
    • Date of Issue:2021/12/07 10:15
  • (EHF) Maintaining the EHF-Series

    • Column Wipe clean with a soft dry cloth or a soft cloth dampened with a mild detergent. •Actuator piston Wipe clean with a soft dry cloth or a sof... Show Detail

    • No:7584
    • Date of Issue:2021/12/07 10:15
  • (EHF) In an Emergency

    In the event of a problem such as abnormal sound or a burning smell from the loading frame, actuator,control unit, or Hydraulic Power Supply, take the follow... Show Detail

    • No:7583
    • Date of Issue:2021/12/07 10:15

21-28 of Total 28

This site uses the FAQ system "PKSHA FAQ", which is a product of PKSHA Communication Inc.