• Font Size
  • S
  • M
  • L

FAQ within [ AGS-X Series ]

11-20 of Total 27

2 / 3page
  • (AGS-X) Resetting the System

    Resetting restores all AGS-Xsettings to factory settings. NOTE: • After restoring factory settings, optional devices must be registered, and the sy... Show Detail

    • No:7991
    • Date of Issue:2020/12/02 14:16
  • (AGS-X) Calibrating Test Force (E-CAL)

    Electronically calibrates (E-CAL) the test force. Calibrating the test force with E-CAL usesprecision resistors built into the calibration cable to apply a s... Show Detail

    • No:7936
    • Date of Issue:2022/01/19 13:10
  • (AGS-X) Alarm Display / Alarm Code

    If an alarm occurs in the AGS-X unit , an alarm sound i s emitted and the alarm screen flashes. Tocancel the alarm, eliminate the cause and press the [STO... Show Detail

    • No:7943
    • Date of Issue:2022/01/19 14:58
  • (AGS-X) Alarm Log

    The main frame stores the alarms have occurred in the last 20 times. The alarm log displays in order fromthe latest. • Pressing the jog button allows... Show Detail

    • No:7941
    • Date of Issue:2022/01/20 09:08
  • (AGS-X) Attaching a Tensile Test Jig

    « Attaching the Upper grip (Non-shift Wedge Type Grips, Screw Type Flat Grips» 1. Screw the tensile joint intothe buttom surface of theload cell. 2.Inser... Show Detail

    • No:7994
    • Date of Issue:2022/01/20 09:24
    • Brached FAQ
  • (AGS-X) Attaching Specimens

    1. Attaching the Specimen 1) Insert the specimen at thecenter of the grip faces. 2) Tighten securely with bothhands. 3) Use jog operations to... Show Detail

    • No:7997
    • Date of Issue:2022/01/20 10:55
  • (AGS-X) Attaching Compression and Bending Test Jigs

    1. Screw in the compression loading jig. 2.Temporarily loosen the set bolt, theninsert the upper compression plate. 3.Insert the boss on the lowercompr... Show Detail

    • No:7999
    • Date of Issue:2022/01/20 11:26
    • Brached FAQ
  • (AGS-X) Setting Crosshead Stroke Limits

    To prevent the crosshead (or attached load cells or jigs) from colliding with anything, secureupper and lower limit collars at respective crosshead upper and... Show Detail

    • No:8001
    • Date of Issue:2022/01/20 13:29
  • (AGS-X) Attaching Specimens (Bending Test)

    1. Adjust the distance between supports. 2. Place the specimen in the center of thesupports. 3. Use jog operations to move the bendingpunch a little above ... Show Detail

    • No:8003
    • Date of Issue:2022/01/20 13:37
  • (AGS-X) Inspection of Safety Equipment

    1.While pressing a jog button to move the crosshead, press the emergency stop button. 2.The crosshead should stop and not restart, even if the jog button is... Show Detail

    • No:8005
    • Date of Issue:2022/01/20 14:07
    • Brached FAQ

11-20 of Total 27

This site uses the FAQ system "PKSHA FAQ", which is a product of PKSHA Communication Inc.