• Font Size
  • S
  • M
  • L

Frequently Referenced FAQ

FAQ within [ AGX-V Series ]

21-30 of Total 31

≪ 3 / 4page ≫
  • (AGX-V) Maintaining the Ball Screws

    Regularly grease the ball screws to keep them lubricated. • Grease name: General grease NLGI No. 2 (Shell Alvania Grease No. 2) Part Number:339-89306-21... Show Detail

    • No:8065
    • Date of Issue:2022/02/01 09:52
  • (AGX-V) Cleaning the Smart Controller

    • Operation buttons Wipe with a soft cloth damped with water. • LCD Touch Panel Lightly wipe with a dry soft cloth or a soft cloth damped with neu... Show Detail

    • No:8067
    • Date of Issue:2022/02/01 09:54
  • (AGX-V) Cleaning the Instrument

    • Table surface Wipe off dirt with a dry soft cloth or a soft cloth damped with neutral detergent. Thenapply antirust oil to the metal surface with a cloth... Show Detail

    • No:8068
    • Date of Issue:2022/02/01 09:55
  • (AGX-V) Usage Time/Counts

    This instrument has the functions to always monitor time/number of times that the testeris used and notify the operator of the information to when a specifie... Show Detail

    • No:8069
    • Date of Issue:2022/02/01 10:05
  • (AGX-V) Alarm Display / Alarm Code

    When the instrument has detected an error, an alarm message is displayed on the LCDtouch panel of the smart controller and on the screen of the special softw... Show Detail

    • No:8071
    • Date of Issue:2022/02/01 10:07
  • (AGX-V) Attaching Test Jigs

    1. Fit the center pin (2) for centering intoa center hole (φ20) at the center of thetable. 2. Place the lower joint (1) aligned withthe center pin (2) and f... Show Detail

    • No:8100
    • Date of Issue:2022/02/01 14:43
    • Brached FAQ
  • (AGX-V) Removing Tensile Test Jigs

    1. Loosen the lock nut with the hook wrench or rotation bar to loosen the upperand lower grips. 2. While holding the upper grip from below, remove the fixin... Show Detail

    • No:8102
    • Date of Issue:2022/02/01 14:43
    • Brached FAQ
  • (AGX-V) Attaching a Specimen

    1. Insert a specimen (3) in between theupper grip faces (2). 2.Rotate the upper grip lever (1) and fixthe specimen (3). Fasten with both hands. ... Show Detail

    • No:8103
    • Date of Issue:2022/02/01 15:28
  • (AGX-V) Attaching Compression Test Jigs

    1. Screw the compression load jig (2) into the load cell (1). 2. Loosen the set screw for the compression load jig temporarily and insert theupper compr... Show Detail

    • No:8104
    • Date of Issue:2022/02/01 15:32
  • (AGX-V) Attaching Bending Test Jigs

    1. Screw the compression load jig (3) into the load cell (2). 2. Loosen the set screw for the compression load jig temporarily and insert thebending pun... Show Detail

    • No:8105
    • Date of Issue:2022/02/01 15:35

21-30 of Total 31

This site uses the FAQ system "PKSHA FAQ", which is a product of PKSHA Technology Inc.