Release User Lockout (LabSolutions DB/CS)
1. Double-click the [User Administration] folder icon in the [Administration Tools] subwindowof the [LabSolutions Main] window. 2. Double click the (R... Show Detail
- No:7096
- Displayed Date:2021/10/07 09:11
- Updated DTM:2022/01/21 15:11
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
Edit Project Settings (LabSolutions DB/CS)
1.Double-click the (Project Administration) icon in the [Administration] sub-windowin the [LabSolutions Main] window. 2. Click [Edit]. 3. M... Show Detail
- No:7095
- Displayed Date:2021/10/07 09:09
- Updated DTM:2022/01/21 15:11
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
New Projects (LabSolutions DB/CS)
1. Double-click the (Project Administration) icon in the [Administration] sub-windowin the [LabSolutions Main] window. 2. Click [Add]. 3... Show Detail
- No:7094
- Displayed Date:2021/10/07 09:06
- Updated DTM:2022/01/21 15:10
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
Change User Settings (LabSolutions DB/CS)
1. In the [User Administration] sub-window, double-click the user ID that needs to bechanged, or select the user and click [Edit]. 2. Make the des... Show Detail
- No:7093
- Displayed Date:2021/10/07 08:58
- Updated DTM:2022/01/21 15:09
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
New User Registration (LabSolutions DB/CS)
1. Double-click the [User Administration] folder icon in the [Administration Tools] subwindowof the [LabSolutions Main] window. 2. Double click the (U... Show Detail
- No:7092
- Displayed Date:2021/10/07 08:56
- Updated DTM:2022/01/21 15:09
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
Edit the Operation Rights in a Group (LabSolutions DB/CS)
1.Double-click the name of the group to change in the [Rights Group Administration] subwindow,or select the rights group and click [Edit]. 2. Add o... Show Detail
- No:7091
- Displayed Date:2021/10/07 08:51
- Updated DTM:2022/01/21 15:08
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
New Rights Groups (LabSolutions DB/CS)
1.Double-click the [User Administration] folder icon in the [Administration Tools] subwindowof the [LabSolutions Main] window. 2.Double click the (Rig... Show Detail
- No:7090
- Displayed Date:2021/10/07 08:36
- Updated DTM:2022/01/21 15:07
- Category: LabSolutions DB/CS , HPLC , GC-MS , Molecular Spectroscopy , GC , Thermal Analysis(TA) , Total Organic Carbon Analysis(TOC) , Software , Software
-
(AGX-V) An optional device does not operate
Check that presence of the optional device has beenregistered correctly. Some types of optional devices requirerestart of the instrument. Turn off the instru... Show Detail
- No:8091
- Displayed Date:2020/12/02 14:16
- Category: AGX-V Series
-
(AGX-V) The test force display is "- - - -"
• The load cell is not recognized. Turn off the power, checkthat the calibration cable is connected appropriately, andturn on the power again. • If the type... Show Detail
- No:8089
- Displayed Date:2020/12/02 14:16
- Category: AGX-V Series
-
(AGX-V) No key input is accepted
No key input is accepted while the instrument is startingup. Wait until the startup is completed. Show Detail
- No:8087
- Displayed Date:2020/12/02 14:16
- Category: AGX-V Series