[JOG UP]and [JOG DOWN] buttons move the crosshead as long as they are pressed. Thecrosshead stops when the button is released. Pressing the [HIGH SPEED] but... Show Detail
- No:8041
- Displayed Date:2022/01/27 14:39
- Category: EZ-Test Series
-
[JOG UP]and [JOG DOWN] buttons move the crosshead as long as they are pressed. Thecrosshead stops when the button is released. Pressing the [HIGH SPEED] but... Show Detail
- No:8040
- Displayed Date:2022/01/27 14:39
- Category: AGS-X Series
-
Once upper and lower mechanical crosshead limits are set, this feature force stops thecrosshead by shutting OFF the motor drive power if the crosshead exceed... Show Detail
- No:7934
- Displayed Date:2022/01/26 14:55
- Category: AGS-X Series
- Brached FAQ
-
1. Switch the AGS-Xpower OFF. 2. Remove any jigs attached to the load cell. 3. Loosen the two fastener screws on the CAL ca ble conn ector on the right sid... Show Detail
- No:7932
- Displayed Date:2022/01/26 09:52
- Category: AGS-X Series
- Brached FAQ
-
(AGS-X) Emergency (Power Failure) Measures
If a malfunction occurs, such as the crosshead not stoppinga burning odor being emitted, or apower failure, take the following actions. Then inspect the sys... Show Detail
- No:7930
- Displayed Date:2022/01/25 11:25
- Updated DTM:2022/01/26 10:02
- Category: AGS-X Series
-
(AGS-X) Maintenance of AGS-X series
1. Operating Panel [Operation Buttons]:Clean with a slighyly wet soft cloth. [VFD Display]:Clean with a slighyly wet soft cloth. 2. Main Frame [Tabl... Show Detail
- No:8012
- Displayed Date:2022/01/20 14:38
- Updated DTM:2022/01/26 14:45
- Category: AGS-X Series
-
(EZ-Test) Maintenance of EZ-Test
1. Operating Panel [Operation Buttons]:Clean with a slighyly wet soft cloth. [VFD Display]:Clean with a slighyly wet soft cloth. 2. Main Frame [Tabl... Show Detail
- No:7710
- Displayed Date:2022/01/20 14:38
- Category: EZ-Test Series
-
(AGS-X) Inspection of Stroke Speed
1. Display the jog speed setting screen by selecting the [System] - [Jog Speed], and make a note ofthe current jog speed. 2.Set the jog speed to 6mm/min. ... Show Detail
- No:8010
- Displayed Date:2022/01/20 14:30
- Category: AGS-X Series
-
(EZ-Test) Inspection of Stroke Speed
1. Display the jog speed setting screen by selecting the [System] - [Jog Speed], and make a note ofthe current jog speed. 2.Set the jog speed to 6mm/min. ... Show Detail
- No:7707
- Displayed Date:2022/01/20 14:30
- Category: EZ-Test Series
-
(AGS-X) Inspection of Test Force
Check wheter the test force is approximately correct or not. (The following numbers are examples.) Use a 100N weight for 1kN to 10kN load cells and a 50N... Show Detail
- No:8008
- Displayed Date:2022/01/20 14:21
- Category: AGS-X Series