1. Attaching the Specimen CAUTION: Make sure the specimen does not hit the lower grip during jog operations. 1) Insert the specimen at the center of t... Show Detail
- No:7695
- Displayed Date:2022/01/20 10:55
- Category: EZ-Test Series
-
(AGS-X) Attaching a Tensile Test Jig
« Attaching the Upper grip (Non-shift Wedge Type Grips, Screw Type Flat Grips» 1. Screw the tensile joint intothe buttom surface of theload cell. 2.Inser... Show Detail
- No:7994
- Displayed Date:2022/01/20 09:24
- Category: AGS-X Series
- Brached FAQ
-
(EZ-Test) Attaching a Tensile Test Jig
« Attaching the Upper grip (Non-shift Wedge Type Grips, Screw Type Flat Grips» 1. Screw the tensile joint intothe buttom surface of theload cell. 2.I... Show Detail
- No:7693
- Displayed Date:2022/01/20 09:24
- Category: EZ-Test Series
- Brached FAQ
-
The main frame stores the alarms have occurred in the last 20 times. The alarm log displays in order fromthe latest. • Pressing the jog button allows... Show Detail
- No:7941
- Displayed Date:2022/01/20 09:08
- Category: AGS-X Series
-
The main frame stores the alarms have occurred in the last 20 times. The alarm log displays in order fromthe latest. • Pressing the jog button allows... Show Detail
- No:7691
- Displayed Date:2022/01/20 09:08
- Category: EZ-Test Series
-
(AGS-X) Alarm Display / Alarm Code
If an alarm occurs in the AGS-X unit , an alarm sound i s emitted and the alarm screen flashes. Tocancel the alarm, eliminate the cause and press the [STO... Show Detail
- No:7943
- Displayed Date:2022/01/19 14:58
- Category: AGS-X Series
-
(EZ-Test) Alarm Display / Alarm Code
If an alarm occurs in theEZ-X unit , an alarm sound i s emitted and the alarm screen flashes. Tocancel the alarm, eliminate the cause and press the [STOP]... Show Detail
- No:7676
- Displayed Date:2022/01/19 14:58
- Updated DTM:2022/01/21 12:40
- Category: EZ-Test Series
-
Once upper and lower mechanical crosshead limits are set, this feature force stops the crossheadby shutting OFF th e motor drive power if the crosshead excee... Show Detail
- No:7674
- Displayed Date:2022/01/19 14:39
- Category: EZ-Test Series
- Brached FAQ
-
(EZ-Test) Attaching Load Cells
1. Switch the EZ-X power OFF. 2. Remove any jigs attached to the load cell. 3. Loosen the two fastener screws on the CAL ca ble conn ector on the right sid... Show Detail
- No:7669
- Displayed Date:2022/01/19 13:22
- Category: EZ-Test Series
- Brached FAQ
-
(AGS-X) Calibrating Test Force (E-CAL)
Electronically calibrates (E-CAL) the test force. Calibrating the test force with E-CAL usesprecision resistors built into the calibration cable to apply a s... Show Detail
- No:7936
- Displayed Date:2022/01/19 13:10
- Category: AGS-X Series