FAQ - Frequently Asked Questions
- Products Search > GC > Consumables
Keyword Search
Frequently Referenced FAQ
FAQ within [ Consumables ]
1-6 of Total 6
-
(GC) Consumables (Capillary Column Connector)
• Capillary Column Connector (ClickTek)(Click) Appearance • Capillary Column Connector (Nut and Ferrule) (Click) • Glasslining Stainless... Show Detail
- No:6553
- Date of Issue:2021/07/08 13:47
- Last Updated:2024/09/30 14:48
-
(GC) Consumables (Glass Insert)
• Glass Insert for Capillary Column(Click) • Glass Insert for OCI / PTV(Click) • Glass Insert for Packed Column(Click) • Connecting Part... Show Detail
- No:6550
- Date of Issue:2021/07/08 13:08
- Last Updated:2024/09/30 14:47
-
(GC) Consumables (Injection Port Septa)
A low-bleed septum is not completely free of bleeding. The type of bleeding that occurs varies with the septum and results in different patterns on chromat... Show Detail
- No:6547
- Date of Issue:2021/07/08 12:43
- Last Updated:2024/09/30 14:48
-
(PAC) Consumables (Chromatopac Recording paper)
- No:6545
- Date of Issue:2021/07/08 09:44
- Last Updated:2024/09/30 14:49
-
(GC) Consumables (Shimadzu Super-Clean Gas Filter)
- No:6542
- Date of Issue:2021/07/08 09:25
- Last Updated:2024/09/30 14:50
-
Syringe Selection Guide If a syringe is being used by hand, a manual syringe should be selected. If a syringe is installed in an AOC autosampler, then choos... Show Detail
- No:6518
- Date of Issue:2021/07/01 13:05
- Last Updated:2024/09/30 14:47
1-6 of Total 6