FAQ - Frequently Asked Questions
Keyword Search
Frequently Referenced FAQ
FAQ within [ Error/Warning ]
-
CARm AFC control irregularity [Error Code:2134 2135 2136 ...
Check that the supply pressure to the AFC is within the range below. Check that the supply pressure is sufficient for the AFC gas to flow. ... Show Detail
- No:5914
- Date of Issue:2021/05/18 15:37
- Last Updated:2023/12/13 13:24
-
Hydrogen sensor is not installed [Error Code:78]
When not using hydrogen sensor, set hydrogen sensor at [N/A]. Screen_Hydrogen-Leak-Check.pdf When using hydrogen sensor, the hardware fails. Turn off th... Show Detail
- No:5913
- Date of Issue:2021/05/18 15:37
- Brached FAQ
-
SCD AD converter initialization was failed [Error Code:6145]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5912
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:59
-
SCD detector leak error [Error Code:6144]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5911
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:58
-
SCD furnace leak error [Error Code:6143]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5910
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:57
-
SCD H2 solenoid valve has been fixed to ON [Error Code:6142]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5909
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:57
-
SCD thermistor error [Error Code:6141]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5908
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:56
-
SCD thermistor temperature exceeds the limit [Error Code:...
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5907
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:55
-
SCD PSU-24V error [Error Code:6124]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5906
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:54
-
Gas Selector# PCB error [Error Code:91 92]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5905
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:53
51-60 of Total 221