FAQ - Frequently Asked Questions
Keyword Search
Frequently Referenced FAQ
FAQ within [ Error/Warning ]
-
AOC-20s can not start[Error Code:6017]
Press the auto injector [RESET] button. Show Detail
- No:6061
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/11 15:28
-
AOC-20s vial setting error[Error Code:6018]
Check and perform the following. • Check for any vial left from the previous sampling. • Redo the teaching using the vial to be used for actual analysis.... Show Detail
- No:6062
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/16 09:20
-
AOC-20s vial returning error[Error Code:6019]
Check and perform the following. • Redo the teaching using the vial to be used for actual analysis. [In case of AOC-30i] AOC-30i_AOC-20sU_SamplerTea... Show Detail
- No:6063
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/16 09:22
-
AOC-20s holding error[Error Code:6020]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:6064
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/11 15:49
-
AOC-20s sample vial removed[Error Code:6021]
Check and perform the following. • Redo the teaching using the vial to be used for actual analysis. [In case of AOC-30i] AOC-30i_AOC-20sU_SamplerTea... Show Detail
- No:6065
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/16 09:24
-
AOC-20s vial is not set[Error Code:6022]
Check and perform the following. • Check the vial No. setting and the actual vial placement. • Check the teaching position setting (if used with a GC other... Show Detail
- No:6066
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/11 15:54
-
AOC model does not match[Error Code:4046]
•Press (HOME) - [Settings] - [Submenu] - [Line Configuration] to display [Line Configuration] screen. •Register the model no. of the AOC being used. Show Detail
- No:6067
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/11 16:10
-
AOC was disconnected[Error Code:4047]
Cause • Analysis was started with the AOC registered to a line while no AOC is actually connected. Solution • When not using the AOC, remove the AOC... Show Detail
- No:6068
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/11 16:17
- Brached FAQ
-
AOCm CHn error[Error Code:6011 6012 6033 6034]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:6069
- Date of Issue:2021/05/18 15:33
- Last Updated:2021/06/11 16:15
-
CARm AFC valve not completely closed[Error Code:2132 2133...
Check that the split line outlet and purge line outlet are not blinded. If the error appears repeatedly even after checking the above, turn off the main pow... Show Detail
- No:6070
- Date of Issue:2021/05/18 15:33
- Last Updated:2023/12/13 13:21
41-50 of Total 221