FAQ - Frequently Asked Questions
Keyword Search
Frequently Referenced FAQ
FAQ within [ Error/Warning ]
-
Cooling fan error [Error Code:35]
The performance decreases in this situation.Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representativ... Show Detail
- No:5894
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:37
-
AUX3-AUX5 A/D error [Error Code:32]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5895
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:37
-
Room temp, Atm. press A/D error [Error Code:31]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5896
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:38
-
COL A/D converter error [Error Code:30]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5897
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:39
-
Clock is initialized [Error Code:29]
Battery for the clock is depleted or the hardware fails. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service ... Show Detail
- No:5898
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:40
-
DC5V is out of range [Error Code:1]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5899
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:41
-
DC24V is out of range [Error Code:2]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5900
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:42
-
Room temperature is out of range [Error Code:5]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5901
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:43
-
Atm. press is out of range [Error Code:6]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5902
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:44
-
Hydrogen sensor init error [Error Code:77]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5903
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:45
151-160 of Total 221