FAQ - Frequently Asked Questions
- Products Search > GC > GC-2030
Keyword Search
GC-2030
Frequently Referenced FAQ
FAQ within [ GC-2030 ]
-
Flow# press/flow offset value is shifted [Error Code:2338...
An error may occur on the pressure sensor. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative. Show Detail
- No:5918
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 01:26
- Category: Error/Warning
-
Flow# valve control irregularity [Error Code:2322 2323 23...
The valve of the flow controller or board may have failed. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/servic... Show Detail
- No:5917
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 01:24
- Category: Error/Warning
-
DetAPCn hydrogen flowing over the specified value [Error ...
Do not open or close the main valve of the supply gas during APC operation. Restart the GC with the gas supplied. Check that the hydrogen gas supply pres... Show Detail
- No:5916
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 01:21
- Category: Error/Warning
-
CARn hydrogen flowing over the specified value [Error Cod...
Ensure that the set values in programs such as Column Oven Temperature Program and Pressure Program are proper. When the set values in the programs are prope... Show Detail
- No:5915
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 01:19
- Category: Error/Warning
-
CARm AFC control irregularity [Error Code:2134 2135 2136 ...
Check that the supply pressure to the AFC is within the range below. Check that the supply pressure is sufficient for the AFC gas to flow. ... Show Detail
- No:5914
- Date of Issue:2021/05/18 15:37
- Last Updated:2023/12/13 13:24
- Category: Error/Warning
-
Hydrogen sensor is not installed [Error Code:78]
When not using hydrogen sensor, set hydrogen sensor at [N/A]. Screen_Hydrogen-Leak-Check.pdf When using hydrogen sensor, the hardware fails. Turn off th... Show Detail
- No:5913
- Date of Issue:2021/05/18 15:37
- Category: Error/Warning
- Brached FAQ
-
SCD AD converter initialization was failed [Error Code:6145]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5912
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:59
- Category: Error/Warning
-
SCD detector leak error [Error Code:6144]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5911
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:58
- Category: Error/Warning
-
SCD furnace leak error [Error Code:6143]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5910
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:57
- Category: Error/Warning
-
SCD H2 solenoid valve has been fixed to ON [Error Code:6142]
Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement. Show Detail
- No:5909
- Date of Issue:2021/05/18 15:37
- Last Updated:2021/06/12 00:57
- Category: Error/Warning
51-60 of Total 225